Estimating tissue strain from signal decorrelation using the correlation coefficient.

نویسندگان

  • T Varghese
  • J Ophir
چکیده

A simple relationship between the correlation coefficient and the applied strain, applicable only at low strains, is presented in this article. This relationship is derived for a Gaussian modulated cosine point spread function. The performance of the strain estimator is analyzed using a theoretical expression for the correlation coefficient along with simulation and experimental results. Both the theoretical and simulation results diverge from the ideal relationship between the strain and the correlation coefficient as the applied strain is increased. Simulation results illustrate that the strain estimate obtained using the correlation coefficient is a biased estimate with a large variability. Experimental results, however, illustrate that strain estimation using the 1-D correlation coefficient estimate is applicable only at high signal-to-noise ratios in the radiofrequency signal and in the absence of lateral and elevational signal decorrelation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation analysis of three-dimensional strain imaging using ultrasound two-dimensional array transducers.

Two-dimensional (2D) transducer arrays represent a promising solution for implementing real time three-dimensional (3D) ultrasound elastography. 2D arrays enable electronic steering and focusing of ultrasound beams throughout a 3D volume along with improved slice thickness performance when compared to one-dimensional (1D) transducer arrays. Therefore, signal decorrelation caused by tissue motio...

متن کامل

Characterization of elastographic noise using the envelope of echo signals.

A theoretical formulation characterizing the noise performance of strain estimation using envelope signals is presented for the cross-correlation based strain estimator in elastography, using a modified strain filter approach. The strain filter describes the relationship among the elastographic signal-to-noise ratio (SNRe), sensitivity, contrast-to-noise ratio and dynamic range for a given reso...

متن کامل

Pii: S0301-5629(01)00472-0

The nonstationary variation in the noise performance of the cross-correlation-based strain estimator due to frequency-dependent attenuation and lateral and elevational signal decorrelation have been addressed theoretically in recent papers using the strain-filter approach. In this paper, we present the experimental verification and corroboration of the nonstationary effects on the strain estima...

متن کامل

An Android Application for Estimating Muscle Onset Latency using Surface EMG Signal

Background: Electromyography (EMG) signal processing and Muscle Onset Latency (MOL) are widely used in rehabilitation sciences and nerve conduction studies. The majority of existing software packages provided for estimating MOL via analyzing EMG signal are computerized, desktop based and not portable; therefore, experiments and signal analyzes using them should be completed locally. Moreover, a...

متن کامل

Compensation for Reflectance Variation in Vessel Density Quantification by Optical Coherence Tomography Angiography

PURPOSE To compensate for reflectance variation when quantifying vessel density by optical coherence tomography angiography (OCTA). METHODS Healthy participants received 6×6-mm macular and 4.5×4.5-mm optic nerve head (ONH) angiography scans on a 70-kHz spectral-domain optical coherence tomography system. The split-spectrum amplitude-decorrelation angiography (SSADA) algorithm was used to comp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 22 9  شماره 

صفحات  -

تاریخ انتشار 1996