Embolic protection device for saphenous vein graft intervention: too early to take off the seat belt.
نویسندگان
چکیده
منابع مشابه
Embolic protection during saphenous vein graft intervention using a second-generation balloon protection device: results from the combined US and European pilot study of the TriActiv Balloon Protected Flush Extraction System.
BACKGROUND Stent placement in saphenous vein bypass grafts is associated with a high incidence of myonecrosis usually resulting from embolization of thrombus and friable atheroma. Embolic protection devices reduce the incidence of adverse events after vein graft stenting. However, first-generation balloon occlusion systems are still associated with a 10% incidence of periprocedural adverse even...
متن کاملAdjuvant therapy of breast cancer in the elderly: does one size fit all?
6. de Feyter PJ. Percutaneous treatment of saphenous vein bypass graft obstructions: a continuing obstinate problem. 7. Bejarano J. Mechanical protection of cardiac microcirculation during percuta-neous coronary interevntion of saphenous vein grafts. Int J Cardiol. In press. 8. Baim DS, Wahr D, George B, et al. Randomized trial of a distal embolic protection device during percutaneous intervent...
متن کاملSaphenous Vein Graft Dissection Using the GuardWire Distal Protection Balloon
The higher rate of periprocedural adverse events and lower rate of event-free survival of saphenous vein graft (SVG) intervention compared with native coronary artery intervention is primarily due to distal embolization. Distal embolic protection devices have been shown to reduce the incidence of no flow/slow flow and procedure related myocardial infarction during percutaneous intervention of d...
متن کاملEmbolic Protection Devices in Saphenous Vein Graft and Native Vessel Percutaneous Intervention: A Review
The clinical benefit of percutaneous intervention (PCI) depends on both angiographic success at the site of intervention as well as the restoration of adequate microvascular perfusion. Saphenous vein graft intervention is commonly associated with evidence of distal plaque embolization, which is correlated with worse clinical outcomes. Despite successful epicardial intervention in the acute MI p...
متن کاملRandomized evaluation of the TriActiv balloon-protection flush and extraction system for the treatment of saphenous vein graft disease.
OBJECTIVES The Protection During Saphenous Vein Graft Intervention to Prevent Distal Embolization (PRIDE) study compared outcomes with the TriActiv System (Kensey Nash Corp., Exton, Pennsylvania), a balloon-protection flush and extraction device, with an embolic protection group during treatment of saphenous venous grafts (SVGs). BACKGROUND Treatment of SVGs with embolic protection reduces ad...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 8 3 شماره
صفحات -
تاریخ انتشار 2015