Quantitative scintigraphy with deconvolutional analysis for the dynamic measurement of hepatic function.

نویسندگان

  • E P Tagge
  • D A Campbell
  • R Reichle
  • D R Averill
  • R M Merion
  • D C Dafoe
  • J G Turcotte
  • J E Juni
چکیده

A mathematical technique known as deconvolutional analysis was used to provide a critical and previously missing element in the computations required to quantitate hepatic function scintigraphically. This computer-assisted technique allowed for the determination of the time required, in minutes, of a labeled bilirubin analog (99mTc-disofenin) to enter the liver via blood and exit via bile. This interval was referred to as the mean transit time (MTT). The critical process provided for by deconvolution is the mathematical simulation of a bolus injection of tracer directly into the afferent blood supply of the liver. The raw data required for this simulation are obtained from the intravenous injection of labeled disofenin, a member of the HIDA family of radiopharmaceuticals. In this study, we perform experiments which document that the simulation process itself is accurate. We then calculate the MTT under a variety of experimental conditions involving progressive hepatic ischemia/reperfusion injury and correlate these results with the results of simultaneously performed BSP determinations and hepatic histology. The experimental group with the most pronounced histologic findings (necrosis, vacuolization, disorganization of hepatic cords) also have the most prolonged MTT and BSP half-life. However, both quantitative imaging and BSP testing are able to identify milder degrees of hepatic ischemic injury not reflected in the histologic evaluation. Quantitative imaging with deconvolutional analysis is a technique easily adaptable to the standard nuclear medicine minicomputer. It provides rapid results and appears to be a sensitive monitor of hepatic functional disturbances resulting from ischemia and reperfusion.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved quantification of salivary gland scintigraphy by means of factor analysis

Introduction: In this study the automatic separation of oral and salivary gland activity and spontaneous secretion by means of factor analysis for quantitative salivary gland scintigraphy is introduced. Methods: After intravenous administration of 99mTc sodium pertechnetate, dynamic scintigraphy was performed. 20 minutes after tracer application 2 ml of lemon juice was delivered to stimulate t...

متن کامل

Quantitative and Qualitative Scintigraphic Measurement of Renal Function in Persian Cat Using 99mTechnetium Ethylenedicysteine and 99mTechnetium Diethylenetriaminepentaacetic

Objective- To consider the use of renal scintigraphic evaluation of kidney function in Persian cat and make a comparison between 99mTechnetium ethylenedicysteine and 99mTechnetium diethylenetriaminepentaacetic in renal scintigraphy. Design- Descriptive study Animals- 6 male healthy adult Persian cats - no clinical sign of renal disorders and prior to presentation. Proce...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

"Hot spot" on hepatic scintigraphy [Persian]

Filling defects are often observed on 99mTc sulfur colloid liver scans. Hot spots are much less frequently seen. Superior vena cava syndrome is the most frequent cause of this finding. In this report 3 patients with S.V.C and budd - Chiari syndrome with HOT SPOT on liver scan are presented. Mechanisms of scintigraphic patterns are reviewed.

متن کامل

99mTc-MIBI scintigraphy in musculoskeletal tumors [Persian]

The aim of this study was to assess the value of 99mTc-hexakis-2-methoxyisobutylisonitrile (MIBI) scintigraphy in patients with clinical and radiologic features of primary or metastatic musculoskeletal tumors. Methods: The scintigraphic findings for 84 patients were compared with the surgical and histologic findings. Each patient underwent three-phase bone scan with 99mTc-methylene diphos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of surgical research

دوره 42 6  شماره 

صفحات  -

تاریخ انتشار 1987