Novel clinical applications of dual energy computed tomography.
نویسندگان
چکیده
Dual energy CT (DECT) was conceived at the very beginning of the computed tomography era. However the first DECT scanner was developed in 2006. Nowadays there are three different types of DECT available: dual-source CT with 80(100) kVp and 140 kVp tubes (Siemens Medical Solution); dual-layer multi-detector scanner with acquisition 120 or 140kVp (Philips Healthcare); CT unit with one rapid kVp switching source and new detector based on gemstone scintillator materials (GE Healthcare). This article describes the physical background and principles of DECT imaging as well as applications of this innovative method in routine clinical practice (renal stone differentiation, pulmonary perfusion, neuroradiology and metallic implant imaging). The particular applications are illustrated by cases from author's material.
منابع مشابه
Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...
متن کاملDetector-based spectral CT with a novel dual-layer technology: principles and applications
Detector-based spectral computed tomography is a novel dual-energy CT technology that employs two layers of detectors to simultaneously collect low- and high-energy data in all patients using standard CT protocols. In addition to the conventional polyenergetic images created for each patient, projection-space decomposition is used to generate spectral basis images (photoelectric and Compton sca...
متن کاملDual‐energy CT in gout – A review of current concepts and applications
Dual-energy computed tomography (DECT) is a relatively recent development in the imaging of gouty arthritis. Its availability and usage have become increasingly widespread in recent years. DECT is a non-invasive method for the visualisation, characterisation and quantification of monosodium urate crystal deposits which aids the clinician in the early diagnosis, treatment and follow-up of this c...
متن کاملA software framework for 3D reconstruction and fracture risk assessment of the proximal femur from dual-energy x-ray absorptiometry
In clinical routine, osteoporosis diagnosis is performed using the areal Bone Mineral Density (aBMD) computed from two-dimensional Dual-energy X-ray Absorptiometry (DXA) images. This measurement of the "projected density" gives a global marker of osteoporosis but is insufficient for an accurate quantification of non-uniform mineral deficiencies. Quantitative Computed Tomography (QCT) is one pos...
متن کاملLow-Dose Dual-Energy Computed Tomography for PET Attenuation Correction with Statistical Sinogram Restoration
Dual-energy (DE) X-ray computed tomography (CT) has been proposed as an useful tool in various applications. One promising application is DECT with low radiation doses used for attenuation correction in positron emission tomography (PET). In low-dose DECT, conventional methods for sinogram decomposition have been based on logarithmic transformations and ignored noise properties, leading to very...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Advances in clinical and experimental medicine : official organ Wroclaw Medical University
دوره 21 6 شماره