Usefulness of target delineation based on the two extreme phases of a four-dimensional computed tomography scan in stereotactic body radiation therapy for lung cancer

نویسندگان

  • Seong Soon Jang
  • Gil Ja Huh
  • Suk Young Park
  • Po Song Yang
  • EunYoun Cho
چکیده

BACKGROUND An evaluation of the usefulness of target delineation based only on the two extreme phases of a four-dimensional computed tomography (4D CT) scan in lung stereotactic body radiation therapy (SBRT). METHODS Seventeen patients treated with SBRT via 4D CT scans for lung cancer were retrospectively enrolled. Volumetric and geometric analyses were performed for the internal target volumes (ITVs) and planning target volumes (PTVs) generated using different respiratory phases (all phases and 2 extreme phases) and setup margins (3 mm and 5 mm). RESULTS As the setup margins were added to the ITVs, the overlap percentage between the PTVs based on all phases and the two extreme phases increased (85.1% for ITVs, 89.8% for PTVs_3 mm, and 91.3% for PTVs_5 mm), and there were no differences according to the tumor parameters, such as the gross tumor volume and 3D mobility. The missing-volume differences for ITVs derived from cone-beam CT images also decreased, with values of 5.3% between ITVs, 0.5% between PTVs_3 mm, and 0.2% between PTVs_5 mm. Compared with the plan based on all phases and a 3 mm margin, the average lung-dose differences found for the PTV based on the two extreme phases and a 5 mm margin were 0.41 Gy for the mean lung dose and 0.93% for V20. CONCLUSIONS Regardless of tumor characteristics, PTV construction based only on the two extreme phases and a 5 mm setup margin may be a useful tool for reducing the clinical workload involved in target delineation in SBRT for lung cancer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

Reconstitution of internal target volumes by combining four-dimensional computed tomography and a modified slow computed tomography scan in stereotactic body radiotherapy planning for lung cancer

BACKGROUND To evaluate the volumetric and geometric differences in the ITVs generated by four-dimensional (4D) computed tomography (CT), a modified slow CT scan, and a combination of these CT methods in lung cancer patients treated with stereotactic body radiotherapy (SBRT). METHODS Both 4D CT and modified slow CT using a multi-slice CT scanner were performed for SBRT planning in 14 patients ...

متن کامل

Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer

PURPOSE This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). MATERIALS AND METHODS 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different IT...

متن کامل

The colossal circumvention of the lung lesion during lung stereotaxy

This is a case report on stereotaxic (Stereotactic Body Radiotherapy-SBRT) for lung cancer located in the left lower lobe (Segment 6, S6). There have been no reports on marked displacement of the peripheral lung cancer during radiotherapy. A pulmonary nodule was discovered on computed tomography (CT) conducted for a persistent cough in an 87-year-old male. According to diagnostic imaging, this ...

متن کامل

Contribution of 68Ga-PSMA PET/CT to targeting volume delineation of prostate cancer treated with conformal radiation therapy: Which SUV threshold is appropriate?

Introduction: Prostate-specific membrane antigen (PSMA) has been demonstrated as a promising tool for specific imaging of prostate cancer (PCa) via positron emission tomography-computed tomography (PET/CT) scanning. Radiation treatment planning (RTP) based on 68Ga-PSMA PET/CT scanning can also lead to some decision modifications.  The specific goal o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015