Four-frame picosecond interferometry system for probing near-critical density CO2 laser-produced plasmas

نویسندگان

  • Chao Gong
  • Sergei Tochitsky
  • Jeremy Pigeon
  • Chan Joshi
چکیده

We describe a four-frame picosecond green laser interferometer developed at the Neptune Laboratory at UCLA. This diagnostic is applied for measuring the dynamics of CO2 laser produced plasmas in a He gas jet. An example of results of the modification of the plasma density profile by the radiation pressure of the laser pulse is presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Picosecond x-ray laser interferometry of dense plasmas.

We present the first results from picosecond interferometry of dense laser-produced plasmas using a soft x-ray laser. The picosecond duration and short wavelength of the 14.7 nm Ni-like Pd laser mitigates effects associated with motion blurring and refraction through millimeter-scale plasmas. This enables direct measurement of the electron-density profile to within 10 microm of the target surfa...

متن کامل

Picosecond-resolution soft-x-ray laser plasma interferometry.

We describe a soft-x-ray laser interferometry technique that allows two-dimensional diagnosis of plasma electron density with picosecond time resolution. It consists of the combination of a robust high-throughput amplitude-division interferometer and a 14.7-nm transient-inversion soft-x-ray laser that produces approximately 5-ps pulses. Because of its picosecond resolution and short-wavelength ...

متن کامل

Refraction effects on x-ray and ultraviolet interferometric probing of laser-produced plasmas

We present a study detailing the effects of refraction on the analysis and interpretation of line-of-site optical probe characterization techniques within laser-produced plasmas. Results using x-ray laser backlit grid deflectometry and ray-tracing simulations illustrate the extent to which refraction can be a limiting factor in diagnosing high-density, short-scale-length plasmas. Analysis is ap...

متن کامل

Diagnostics of Dielectric Barrier Discharge at Atmospheric Pressure by Laser Spectroscopic Measurements

Spatial distribution of electron density inside parallel plate dielectric barrier discharge (DBD) is discussed in this presentation by using CO2-laser heterodyne interferometry measurement. This interferometry measurement has been used for low pressure plasmas and applied to DC microplasmas at atmospheric pressure recently. To derive the electron density inside pulsed plasmas like DBD, we used ...

متن کامل

Laser-plasma Interaction Studies Using above Critical Density Gas Jet Plasmas and a Multi-tw Co2 Laser*

CO2 laser-plasma interaction provides a unique parameter space for particle acceleration in a gas jet plasma taking place at a critical plasma density ncr ~ 10 cm and even at higher densities (3~10 ncr) of 10μm radiation. Here we report the latest results of our study of electron acceleration in a wide range of plasma densities 1~10 ncr using a multi-TW CO2 laser system at the UCLA Neptune Labo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014