Inspiratory efforts achieved in use of the Technosphere insulin inhalation system.
نویسندگان
چکیده
OBJECTIVE The Technosphere Insulin (TI) inhalation system comprises TI powder premetered into unit dose cartridges and the patient-friendly, reusable, breath-powered MedTone inhaler. This high-resistance system uses a patient's inspiratory effort to effect TI powder de-agglomeration and promote subsequent deep-lung delivery. This study reports on flow and pressure data achieved by patients with diabetes using the MedTone system. METHOD MedTone inhalers containing empty cartridges were adapted with pneumotach measuring devices to capture inhalation profiles. The measuring apparatuses had negligible impact on the nominal MedTone system resistance level of 0.117 kPa(0.5)/liters/min. Each of 56 subjects inhaled twice to mimic TI clinical study dosing instructions. Achieved inhalation profiles were characterized by peak inspiratory flow (PIF), peak inspiratory pressure (PIP), and average pressure drop from the time of PIP to 4 s (P(avg)). RESULTS The achieved mean PIF (+/- standard deviation [SD]) in all subjects was 26.74 (+/-6.06) liters/min after the first inhalation and was similar to the mean PIF of 26.25 (+/-6.23) liters/min achieved after the second inhalation. Mean PIP (+/-SD) achieved by subjects was 8.49 (+/-2.86) and 8.1 (+/-2.99) kPa, and mean P(avg) drop (+/-SD) in all subjects was 6.53 (+/-2.24) and 6.09 (+/-2.08) kPa after the respective inhalations. CONCLUSION Patients with diabetes demonstrated consistent inhalation efforts over two inhalations using the MedTone system. The achieved PIFs and PIPs demonstrate the capacity of this population to obtain sufficient inspiratory effort necessary for delivery of TI using the MedTone inhaler. Adequate postpeak pressures were also revealed, further supporting reliable and sustained inhalation efforts.
منابع مشابه
Evaluation of novel particles as an inhalation system for GLP-1.
AIM The feasibility of administering native glucagon-like peptide 1 (GLP-1) as GLP-1 Technosphere Inhalation Powder for diabetes therapy has been demonstrated in a rat model. METHODS GLP-1 Technosphere Inhalation Powders containing 5, 10 and 15% GLP-1 were prepared and administered to healthy female Sprague-Dawley rats and to male Zucker diabetic obese rats. Rats received a single dose of GLP...
متن کاملPlace of technosphere inhaled insulin in treatment of diabetes
Technosphere insulin (TI), Afrezza, is a powder form of short-acting regular insulin taken by oral inhalation with meals. Action of TI peaks after approximately 40-60 min and lasts for 2-3 h. TI is slightly less effective than subcutaneous insulin aspart, with mean hemoglobin A1c (HbA1c) reduction of 0.21% and 0.4%, respectively. When compared with technosphere inhaled placebo, the decrease in ...
متن کاملTechnosphere insulin: defining the role of Technosphere particles at the cellular level.
BACKGROUND Technosphere Insulin (TI) is a novel inhalation powder for the treatment of diabetes mellitus. Technosphere Insulin delivers insulin with an ultra rapid pharmacokinetic profile that is distinctly different from all other insulin products but similar to natural insulin release. Such rapid absorption is often associated with penetration enhancers that disrupt cellular integrity. METH...
متن کاملEfficacy and Safety of Technosphere Inhaled Insulin Compared With Technosphere Powder Placebo in Insulin-Naive Type 2 Diabetes Suboptimally Controlled With Oral Agents
OBJECTIVE This double-blind, placebo-controlled, randomized, multicenter, parallel-group study compared the efficacy, safety, and tolerability of Technosphere insulin with Technosphere powder as placebo in insulin-naive type 2 diabetic patients whose diabetes was suboptimally controlled with oral antidiabetic agents. RESEARCH DESIGN AND METHODS Patients (n = 126) were randomly assigned to 12 ...
متن کاملInhaled Technosphere insulin in comparison to subcutaneous regular human insulin: time action profile and variability in subjects with type 2 diabetes.
BACKGROUND This study assessed time action profile and within- and between-subject variability of inhaled Technosphere Insulin (TI) compared with subcutaneous regular human insulin (sc RHI). METHODS Thirteen subjects with type 2 diabetes (age 56 +/- 7 years, body mass index 30.4 +/- 3.0 kg.m(-2); hemoglobin A1c 6.9 +/- 0.9%; mean +/- SD) participated in this six-period crossover isoglycemic g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of diabetes science and technology
دوره 3 5 شماره
صفحات -
تاریخ انتشار 2009