Magnetoencephalographic Study on Forward Suppression by Ipsilateral, Contralateral, and Binaural Maskers

نویسندگان

  • Tadashi Nishimura
  • Yuka Uratani
  • Tadao Okayasu
  • Seiji Nakagawa
  • Hiroshi Hosoi
چکیده

When two tones are presented in a short time interval, the response to the second tone is suppressed. This phenomenon is referred to as forward suppression. To address the effect of the masker laterality on forward suppression, magnetoencephalographic responses were investigated for eight subjects with normal hearing when the preceding maskers were presented ipsilaterally, contralaterally, and binaurally. We employed three masker intensity conditions: the ipsilateral-strong, left-right-balanced, and contralateral-strong conditions. Regarding the responses to the maskers without signal, the N1m amplitude evoked by the left and binaural maskers was significantly larger than that evoked by the right masker for the left-strong and left-right-balanced conditions. No significant difference was observed for the right-strong condition. Regarding the subsequent N1m amplitudes, they were attenuated by the presence of the left, binaural, and right maskers for all conditions. For the left- and right-strong conditions, the subsequent N1m amplitude in the presence of the left masker was smaller than those of the binaural and right maskers. No difference was observed between the binaural and right masker presentation. For left-right-balanced condition, the subsequent N1m amplitude decreased in the presence of the right, binaural, and left maskers in that order. If the preceding activity reflected the ability to suppress the subsequent activity, the forward suppression by the left masker would be superior to that by the right masker for the left-strong and left-right-balanced conditions. Furthermore, the forward suppression by the binaural masker would be expected to be superior to that by the left masker owing to additional afferent activity from the right ear. Thus, the current results suggest that the forward suppression by ipsilateral maskers is superior to that by contralateral maskers although both maskers evoked the N1m amplitudes to the same degree. Additional masker at the contralateral ear can attenuate the forward suppression by the ipsilateral masker.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Masker laterality and cueing in forward-masked intensity discrimination.

Forward-masked intensity discrimination was measured as a function of level in experiments designed to reveal insights into the mechanism(s) underlying the midlevel elevation of the Weber fraction. The standard and maskers were 1.0-kHz tones that were separated by 100 ms. Performance was measured for listeners with normal hearing using an adaptive procedure. In experiment 1, intensity discrimin...

متن کامل

Why Do Forward Maskers Affect Auditory Intensity Discrimination? Evidence from "Molecular Psychophysics"

Nonsimultaneous maskers can strongly impair performance in an auditory intensity discrimination task. Using methods of molecular psychophysics, we quantified the extent to which (1) a masker-induced impairment of the representation of target intensity (i.e., increase in internal noise) and (2) a systematic influence of the masker intensities on the decision variable contribute to these effects....

متن کامل

Inhibitory influence of the dorsal nucleus of the lateral lemniscus on binaural responses in the rat's inferior colliculus.

The contribution of the dorsal nucleus of the lateral lemniscus (DNLL) to binaural processing was examined by recording single-unit activity in the rat's inferior colliculus before, during, and after a reversible block of the excitatory activity in DNLL by local injection of kynurenic acid. Recordings were made from the central nucleus of the inferior colliculus with glass micropipettes filled ...

متن کامل

Spatial tuning to sound-source azimuth in the inferior colliculus of unanesthetized rabbit.

Despite decades of research devoted to the study of inferior colliculus (IC) neurons' tuning to sound-source azimuth, there remain many unanswered questions because no previous study has examined azimuth tuning over a full range of 360° azimuths at a wide range of stimulus levels in an unanesthetized preparation. Furthermore, a comparison of azimuth tuning to binaural and contralateral ear stim...

متن کامل

Binaural interaction and the octave illusion.

The auditory octave illusion arises when dichotically presented tones, one octave apart, alternate rapidly between the ears. Most subjects perceive an illusory sequence of monaural tones: A high tone in the right ear (RE) alternates with a low tone, incorrectly localized to the left ear (LE). Behavioral studies suggest that the perceived pitch follows the RE input, and the perceived location th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013