Cryogenic Composite Detectors for the Dark Matter Experiments CRESST and EURECA

نویسندگان

  • S. Roth
  • W. Westphal
چکیده

Weakly Interacting Massive Particles (WIMPs) are candidates for non-baryonic Dark Matter. WIMPs are supposed to interact with baryonic matter via scattering off nuclei producing a nuclear recoil with energies up to a few 10 keV with a very low interaction rate of ∼10−6 events per kg of target material and day in the energy region of interest. The Dark Matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) and the EURECA project (European Underground Rare Event Calorimeter Array) are aimed at the direct detection of WIMPs with the help of very sensitive modularised cryogenic detectors that basically consist of a transition edge sensor (TES) in combination with a massive absorber crystal. In the CRESST experiment the search for coherent WIMP-nucleon scattering events is validated by the detection of two processes. In the scintillating absorber single crystal, CaWO4, heat (phonons) and scintillation light are produced and detected with two independent cryogenic detectors: a phonon channel and a separate light channel. The development of such cryogenic detectors and the potential ton-scale production are investigated in this paper. To decouple the TES production from the choice of the target material in order to avoid heating cycles of the absorber crystal and to allow pretesting of the TESs, a composite detector design (CDD) for the detector production has been developed and studied. An existing thermal detector model has been extended to the CDD, in order to investigate, understand, and optimize the performance of composite detectors. This extended model, which has been worked out in detail, can be expected to provide a considerable help when tailoring composite detectors to the requirements of various

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermal detector model for cryogenic composite detectors for the dark matter experiments CRESST and EURECA

The CRESST (Cryogenic Rare Event Search with Superconducting Thermometers) and the EURECA (European Underground Rare Event Calorimeter Array) experiments are direct dark matter search experiments where cryogenic detectors are used to detect spin-independent, coherent WIMP (Weakly Interacting Massive Particle)-nucleon scattering events by means of the recoil energy. The cryogenic detectors use a...

متن کامل

Development of cryogenic phonon detectors based on CaMoO4 and ZnWO4 scintillating crystals for direct dark matter search experiments

This work reports on the development of the first phonon detectors based on CaMoO4 and ZnWO4 scintillating crystals for the CRESST-II experiment. In particular, a novel technique for the production of the ZnWO4 phonon detector with a separate thermometer carrier was investigated. The influence of the thermal and mechanical treatment on the scintillation light output of CaMoO4 and ZnWO4 crystals...

متن کامل

GluedCaWO4 Detectors for the CRESST-II Experiment

The Cryogenic Rare Event Search with Superconducting Thermometers Phase II (CRESST-II) at the L.N.G.S in Italy is searching for Dark Matter using low-temperature calorimeters. These detectors allow to discriminate di erent particles by simultaneous measurement of phonons and scintillation light. The sensors used consist of superconducting tungsten thinlm thermometers, which measure the thermal ...

متن کامل

Energy-dependent light quenching in CaWO4 crystals at mK temperatures

ScintillatingCaWO4 single crystals are a promising multi-element target for rare-event searches and are currently used in the direct dark matter experiment CRESST (Cryogenic Rare Event Search with Superconducting Thermometers). The relative light output of different particle interactions in CaWO4 is quantified by quenching factors (QFs). These are essential for an active background discriminati...

متن کامل

Discrimination between Nuclear Recoils and Electron Recoils by Simultaneous Detection of Phonons and Scintillation Light

We have developed a detector, consisting of a cryogenic calorimeter with a scintillating crystal as absorber, and a second calorimeter for the detection of the scintillation light, both operated at 12 mK. Using a CaWO4 crystal with a mass of 6 g as scintillating absorber, we have achieved a discrimination of nuclear recoils against electron recoils with a suppression factor of 99.7% at energies...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008