Measurement and Simulation of the Umer Beam in the Source Region*

نویسندگان

  • I. Haber
  • S. Bernal
  • R. A. Kishek
  • P. G. O’Shea
  • B. Quinn
  • M. Reiser
  • Y. Zou
  • A. Friedman
  • D. P. Grote
چکیده

As the beam propagates in the University of Maryland Electron Ring (UMER) complex transverse density structure including halos has been observed. A primary objective of the experiment is to understand the evolution of a space-charge-dominated beam as it propagates over a substantial distance. It is therefore important to understand which details of the beam structure result from propagation of the beam in the ring and which characteristics result from the specific details of the initial distribution. Detailed measurements of the initial beam characteristics have therefore been performed. These include direct measurement of the density using a phosphor screen, as well as pepper pot measurements of the initial transverse distribution function. Detailed measurements of the distribution function have also been obtained by scanning a pinhole aperture across a beam diameter, and recording phosphor screen pictures of the beam downstream of the pinhole. Simulations of the beam characteristics in the gun region have also been performed using the WARP P.I.C. code. From these simulations, the observed behavior has been attributed to a combination of perturbations to the transverse distribution by a cathode grid that is used to modulate the beam current, as well as the complex transverse dynamics that results from the combination of the nonlinear external focusing fields of the gun structure and the nonlinear space charge forces.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation of Siemens Primus plus Linac for 6 and 18 MV Photon Beams

Objective: The aim of the present study is to simulate 6 MV and 18 MV photon beam energies of a Siemens Primus Plus medical linear accelerator (Linac) and to verify the simulation by comparing the results with the measured data.Methods: The main components of the head of Siemens Primus Plus linac were simulated using MCNPX Monte Carlo (MC) code. To verify the results, experimental data of perce...

متن کامل

Developement a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Background: Monte Carlo (MC) modeling of a linear accelerator is a prerequisite for Monte Carlo dose calculations in external beam radiotherapy. In this study, a simple and efficient model was developed for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code Materials and methods: The head of Elekta SL-25 linac was simulated for 6 and 18 MV photon beams using MCNP4C MC code. Energ...

متن کامل

Thermal Analysis of Laser Hardening for Different Moving Patterns

Transient thermal field in laser surface hardening treatment of medium carbon steel was analyzed by employing both three-dimensional analytical model and finite element model. In finite element model the laser beam was considered as a moving plane heat flux to establish the temperature rise distribution in the work-piece, while in analytical model laser beam was considered as an internal heat s...

متن کامل

Computer Simulation of the Umer Electron Gun*

* Work supported by the U. S. Department of Energy at NRL under contracts DE-AI02-93ER40799 and DE-AI02-94ER54232, at U. Md. under DE-FG02-92ER54178 and DE-FG02-94ER40855, and at the HIFVNL under DE-AC03-76SF00098 and W-7405-Eng-48. Abstract An important feature of the UMER experimental program [1,2] is the continuing use of comparison between computer simulation and experimental measurement. T...

متن کامل

The study of neutron interactions with soft tissue using Monte Carlo simulation using the source PF

The most important part of neutron therapy treatment (NCT1) is to achieve a beam of neutrons with suitable energy and intensity, as well as the least pollution and damage. In this study, in order to correct the neutron spectrum from D-D fusion and its use in neutron therapy, a set of different materials which are called the Beam Shaping Assembly (BSA) was placed in the direction of energy 2.45 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005