Uncertainty Quantification of Cochlear Implant Insertion from CT Images
نویسندگان
چکیده
Cochlear implants (CI) are used to treat severe hearing loss by surgically inserting an electrode array into the cochlea. Since current electrodes are designed with various insertion depth, ENT surgeons must choose the implant that will maximise the insertion depth without causing any trauma based on preoperative CT images. In this paper, we propose a novel framework for estimating the insertion depth and its uncertainty from segmented CT images based on a new parametric shape model. Our method relies on the posterior probability estimation of the model parameters using stochastic sampling and a careful evaluation of the model complexity compared to CT and μCT images. The results indicate that preoperative CT images can be used by ENT surgeons to safely select patient-specific cochlear implants.
منابع مشابه
Investigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملStandardization of CT depiction of cochlear implant insertion depth.
BACKGROUND AND PURPOSE Imaging a cochlear implant with CT is challenging because of implant-induced artifacts, anatomic cochlear variations, and lack of standard terminology for cochlear anatomy. The purposes of this project were to determine whether the cochlear implant tip was more accurately located on oblique CT reformations than on standard images, to review radiology reports for accurate ...
متن کاملHigh-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants.
Radiologic assessment of cochlear implants can be limited because of metallic streak artifacts and the high attenuation of the temporal bones. We report on 14 patients with 18 cochlear implants (17 Med-El standard 31.5-mm arrays, 1 Med-El medium 24-mm array) who underwent flat panel CT with the use of high-resolution secondary reconstruction techniques. Flat panel CT depicted the insertion site...
متن کاملCorrelation between histologic and radiographic reconstruction of intracochlear electrode position in human temporal bones.
In our laboratory, human temporal bone specimens from patients who in life have undergone cochlear implantation are routinely processed with the implant in situ, embedded in Araldite, sectioned at 20 µm and serially photographed during cutting, stained with toluidine blue and mounted on glass slides. From the images, two-dimensional and three-dimensional reconstructions can be made and a very a...
متن کاملCT and MR Imaging Cochlear Distance Measurements May Predict Cochlear Implant Length Required for a 360° Insertion
S.E.J. Connor D.J. Bell R. O’Gorman A. FitzgeraldO’Connor BACKGROUND AND PURPOSE: A preoperative prediction of the 360° point insertion depth would aid the planning of electric acoustic stimulation (EAS) implantation. The purpose of this study was to establish whether the distance between the round window and the opposite cochlear wall on CT or MR imaging may be used to predict the length of a ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016