Direct noninvasive measurement of tear oxygen tension beneath gas-permeable contact lenses in rabbits.

نویسندگان

  • D M Harvitt
  • J A Bonanno
چکیده

PURPOSE To develop a noninvasive measurement of tear oxygen tension and to determine tear oxygen tension and calculated oxygen flux rates during wear of contact lenses of varying oxygen transmissibility (Dk/L). METHODS The basis of the tear oxygen tension (PO2) measurement is phosphorescence quenching of Pd-meso-tetra-(4-carboxyphenyl) porphine by oxygen. A fiber-optic bundle, positioned approximately 2 mm from a cuvette or from the corneal surface, delivers an excitation flash (< 4 microseconds, 539 +/- 23 nm) and collects the phosphorescence emission (> 645 nm) of the dye at 1 MHz for 2 ms. Porphine (500 microM) + 1% albumin is instilled directly into the tears of a sedated rabbit, and phosphorescence is measured before and after contact lens insertion. RESULTS Phosphorescence intensity decay lifetimes are related inversely to PO2 and follow the Stern-Volmer relationship. Calibration control experiments revealed a temperature effect on lifetime of 1% per degree, dye concentration independence over a 100-fold dilution, and no significant pH effect between 6.8 and 7.9. Phosphorescence lifetimes indicated that tear PO2 beneath contact lenses reached steady state within 3 to 8 minutes. Mean steady state tear PO2 (mm Hg +/- SE; N > 7) beneath contact lenses was: polymethylmethacrylate (Dk/L = 0), tear PO2 = 0.58 +/- 0.22; Oxyflow f30 (Dk/L = 15.3), tear PO2 = 27.7 +/- 3.4; Fluorex 700 Dk/L = 30), tear PO2 = 52.5 +/- 3.8; Oxyflow 151 (Dk/L = 51.9), tear PO2 = 78.7 +/- 23.9. Steady state tear PO2 beneath an Oxyflow f30 after application of topical anesthetic and 10 minutes of lens wear was 41 +/- 1.2 mm Hg, significantly higher than without anesthetic. CONCLUSIONS Phosphorescence-based measurements allow the direct, sensitive, and noninvasive assessment of oxygen availability beneath a contact lens. Oxygen levels beneath permeable contact lenses found by direct measurement are significantly lower than what mathematical models predict. The measured values, however, are close to PO2 estimates using the equivalent oxygen percentage (EOP) technique. Tear PO2 measurements may be used to examine metabolic disturbances as shown by reduced oxygen consumption rates after application of topical anesthetic.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of human corneal oxygen consumption by noninvasive measurement of tear oxygen tension while wearing hydrogel lenses.

PURPOSE To devise a procedure for direct estimation of corneal oxygen consumption in human subjects. METHODS Tear oxygen tension (PO2) was measured at the posterior surface of two standard hydrogel contact lenses (38% water, 0.2 and 0.06 mm thick, oxygen transmissibility [Dk/t] = 4.2 and 14 x 10(-9) cm x mL O2/mL x sec x torr) and one newly available hydrogel-silicone polymer lens (Dk/t = 99 ...

متن کامل

Measurement of post-lens tear thickness.

PURPOSE A method to measure the tear film beneath a soft contact lens, referred to as post-lens tear thickness (PLTT), would have many applications to contact lens research. In this study a noninvasive technique for measuring the PLTT is presented. METHODS The feasibility of measuring the tear layer by optical pachometry was first assessed using a model eye. The baseline corneal thickness (B)...

متن کامل

On-eye measurement of optical performance of rigid gas permeable contact lenses based on ocular and corneal aberrometry.

PURPOSE Our aim was to obtain a complete description of the interactions of rigid gas permeable (RGP) contact lenses with the optics of normal eyes. METHODS We measured total and anterior-surface aberrations in four subjects, who were all long-term RGP contact lens wearers. The anterior-surface wave aberration was obtained from videokeratographic elevation maps, and ocular wave aberration was...

متن کامل

Immunoglobulin Concentration in Tears of Contact Lens Wearers

PURPOSE To evaluate changes in the concentration of tear immunoglobulins in contact lens wearers. METHODS A total of 45 cases including 23 contact lens wearers (43 eyes) and 22 age and sex matched healthy controls having no ocular pathology were studied for immunoglobulins (IgA, IgG, IgM) in their tears by single radial immunodiffusion method. RESULTS Most of the cases used soft (56.6%) and...

متن کامل

Impression Cytology in Different Types of Contact Lens Users

This study compared tear function tests and cytologic changes on the conjunctival surface in asymptomatic patients wearing contact lens of different materials. Included in this study were 40 eyes wearing daily wear 4 week replacement hydrogel (H) lenses, 32 eyes wearing silicone hydrogel (SiH) lenses, 18 eyes wearing rigid gas-permeable (RGP) lenses, and 21 healthy eyes (no lenses) as the contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 1996