Glycated haemoglobin A1c measurement in stored whole blood sample is reliable for clinical use.

نویسندگان

  • C E Ezenwaka
  • D Seales
  • R Surujlal
  • R P Mathura
چکیده

Glycated haemoglobin A1c (HbA1c) gives an integrated plasma glycaemia for the previous 2-3 months and its measurement is central in the management of diabetic patients. However in many developing countries because kits/regents or expertise for HbA1c measurement are not always available and the test must be conducted on fresh whole blood samples, HbA1c tests are not routinely performed Thus, this study aimed to determine if the degradation products from whole blood sample storage are significant enough to compromise the diagnostic value of HbA1c measurements. Two hundred and thirty-one fresh whole blood samples with pre-determined HbA1c values were stored at between 2-8 degrees C and using boronate affinity immunoassay technique, HbA1c values were then measured in the same whole blood samples after 20 days of storage. The results showed that there were no significant differences in the mean values of the initial HbA1c measurement and the values obtained after storage (7.5 +/- 2.0 vs. 7.5 +/- 2.1, p > 0.05) and this was irrespective of gender. Furthermore, irrespective of gender there were significant correlations between the HbA1c values measured in fresh whole blood samples and values obtained after storage (r = 0.83, p < 0.01). Therefore, based on these findings and other previous reports, the effect of storage degradation product was not significant enough to compromise the clinical or research use of HbA1c test results from stored whole blood samples. However, we recommend that diagnostic laboratories should evaluate their HbA1c measurement techniques for HbA1c determination in stored whole blood samples. Any persistent upward or downward bias in stored whole blood samples should be reported to guide the physician in interpreting HbA1c results from stored whole blood samples from that laboratory and/or technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of glycated hemoglobin A1c from dried blood by turbidimetric immunoassay.

BACKGROUND Glycated hemoglobin A1c (A1C) is an important marker in the diagnosis and treatment of diabetes. Dried blood measurement of A1C is useful in large scale epidemiological evaluation of A1C, especially to assess the impact of intervention programs. The possibility of using dried blood for measurement of A1C by the immunoturbidimetric method was explored in the present study. METHOD Bl...

متن کامل

Glycated haemoglobin; past, present, and future are we ready for the change.

Glycated haemoglobin has been in use to monitor control of blood glucose in diabetic patients for about three decades. It provides an average blood glucose level during preceding 10-12 weeks. It is a very convenient blood test, can be done in any clinical setting regardless of prandial state. There were thirty different laboratory methods available to measure glycated haemoglobin with significa...

متن کامل

Glycated haemoglobin in diabetic women with and without HIV infection: data from the Women's Interagency HIV Study.

BACKGROUND Limited data suggest that glycated haemoglobin (haemoglobin A1c; A1C) values might not reflect glycaemic control accurately in HIV-infected individuals with diabetes. METHODS We evaluated repeated measures of paired fasting glucose and A1C values in 315 HIV-infected and 109 HIV-uninfected diabetic participants in the Women's Interagency HIV Study. Generalized estimating equations u...

متن کامل

Translating the A1C Assay

In the clinical management of diabetes, the A1C assay has become indispensable. Used worldwide to monitor chronic glycemia, the assay is an essential tool to determine whether a patient has achieved the core goal of therapy for diabetes: a marked and sustained reduction in plasma glucose to achieve as close to a normal level as can be safely attained. With the publication of the A1c-Derived Ave...

متن کامل

Affinity binding assay of glycohemoglobin by two-dimensional centrifugation referenced to hemoglobin A1c.

We describe an automated assay of glycohemoglobin performed with the Abbott Vision analyzer. The assay is based on batch affinity-extraction with 3-aminophenylboronic acid-derivatized agarose beads. Reagents are packaged in a disposable test pack. Whole-blood specimens are hemolyzed with saponin within a glass capillary tube inserted into the test pack. The sample is automatically diluted with,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The West Indian medical journal

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 2009