Pii: S1010-7940(00)00324-9

نویسندگان

  • Christos Alexiou
  • Angus McDonald
  • Stephen M. Langley
  • Malcolm J.R. Dalrymple-Hay
  • Marcus P. Haw
  • James L. Monro
چکیده

Objective: The choice of the most appropriate substitute in children with irreparable aortic valve lesions remains controversial. The aim of this study was to assess early and late outcomes following aortic valve replacement (AVR) with mechanical prostheses in children. Paitents: Fifty-six patients (42 male, 14 female, mean age 11.2, range 1±16 years) undergoing AVR with mechanical prostheses between October 1972 and January 1999 were evaluated. Thirty-six patients (64.2%) underwent previous cardiac surgery. Disease aetiology was congenital in 47 patients (congenital aortic stenosis in 33, and other congenital abnormalities in 14) (83.9%), infective in four (7.1%), rheumatic in two (3.4%), and three (5.3%) had connective tissue disorders. Haemodynamic indication for AVR was aortic regurgitation (AR) in 24 (42.8%), aortic stenosis (AS) in 22 (39.2%) and mixed disease in ten (17.8%). Twenty-eight patients (50.0%) were in New York Heart Association (NYHA) class III-IV before surgery. Concomitant procedures were performed in 31 patients (55.3%), including aortic root enlargement in 28 (50%). The mean size of implanted valves was 22.4 mm (range 17±27 mm). All patients received long-term anticoagulation treatment with sodium warfarin, aiming to maintain an international normalized ratio (INR) between 2.5±3.0. The mean follow-up was 7.3 years (range 0± 26, total 405 patient-years). Results: Operative mortality was 5.3% (three patients). Three patients developed complete heart block requiring pacing, two of them permanently. Late events included valve thrombosis (one), transient stroke (one), paravalvular leak of a mitral prosthesis (one), aneurysm of sinus of Valsava (one) and pannus ingrowth (one). There was no major haemorrhagic event. Five patients required reoperation (8.9%), but none due to outgrowth of the valve. Regarding actuarial freedom from thrombo-embolism, any valve-related event and re-operation at 20 years was 93, 86.6 and 86.4%. There were three late deaths. Actuarial survival, including operative mortality, at 10 and 20 years was 91 and 84.9%. The actuarial survival for the group of the patients with congenital AS (n ˆ 33) at 10 and 20 years was 93.5%, whereas for the children with other congenital heart problems (n ˆ 14) this was 85.7 and 64.3% (P ˆ 0:09). At the latest clinical evaluation, 44 children were in NYHA class I and six were in class II. The mean gradient across the aortic prosthetic valve on echocardiography was 17.9 mmHg (range 0±47 mmHg). Conclusions: Mechanical AVR, with enlargement of the aortic root if necessary, remains an excellent treatment option in children. It is associated with acceptable operative mortality, low incidence of late events and re-operation, and provides good longterm survival. It clearly represents a good alternative to available biological substitutes, including the pulmonary autograft (Ross procedure). q 2000 Elsevier Science B.V. All rights reserved.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S1010-7940(00)00316-x

A direct laryngoscope-assisted technique of saphenous vein harvesting by tunnelling method is described. This technique provides better exposure through small incisions, thus reducing the chances of trauma to the vein due to excessive handling. The equipment used is inexpensive and readily available. q 2000 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(00)00634-5

Akin Kuzucu*, Omer Soysal, Cengiz Yakinci, N. Engin Aydin Department of Thoracic and Cardiovascular Surgery, Inonu University Faculty of Medicine, Turgut Ozal Medical Center, Malatya, Turkey Department of Pediatrics, Inonu University Faculty of Medicine, Turgut Ozal Medical Center, Malatya, Turkey Department of Pathology, Inonu University Faculty of Medicine, Turgut Ozal Medical Center, Malatya...

متن کامل

Pii: S1010-7940(02)00020-9

Electrocautery has a potential risk of serious pacemaker dysfunction in patients with implanted pacemaker. Here we present the safe and efficient use of ultrasonic scalpel (Harmonic scalpel) for the first time in a patient with implanted pacemaker undergoing open-heart reoperation. q 2002 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(00)00338-9

A 54-year-old woman with myoepithelioma, a very rare tumor of the lung, is reported. The patient presented with exertional dyspnea, cough and intermittent pleuritic chest pain. Her chest X-ray revealed a peripheral 2 cm mass in the left lower lung zone. Bronchoscopy was normal. She underwent thoracotomy in which a wedge-resection was performed. Histological examination of the specimen demonstra...

متن کامل

Pii: S1010-7940(01)00993-9

The length of the in situ right internal mammary artery (RIMA) often restricts its use as a graft to distal marginal arteries. We describe herein a retrocaval supra-azygous extra-pleural passage of the RIMA that allows a significant gain in length. We report our experience in 30 patients with distal marginal lesions or with large hearts. q 2001 Elsevier Science B.V. All rights reserved.

متن کامل

Pii: S1010-7940(01)01137-x

We report the laparoscopic transhiatal thoracic duct ligation to solve postoperative chylothorax after right total pleurectomy for malignant diffuse mesothelioma. q 2002 Elsevier Science B.V. All rights reserved.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000