A comparison of ground reaction forces determined by portable force-plate and pressure-insole systems in alpine skiing.
نویسندگان
چکیده
For the determination of ground reaction forces in alpine skiing, pressure insole (PI) systems and portable force plate (FP) systems are well known and widely used in previous studies. The purposes of this study were 1) to provide reference data for the vertical component of the ground reaction forces (vGRF) during alpine skiing measured by the PI and FP systems, and 2) to analyze whether the differences in the vGRF measured by the PI and the FP depend on a skier's level, skiing mode and pitch. Ten expert and ten intermediate level skiers performed 10 double turns with the skiing technique "Carving in Short Radii" as High Dynamic Skiing mode and "Parallel Ski Steering in Long Radii" as Low Dynamic Skiing mode on both the steep (23 °) and the flat (15 °) slope twice. All subjects skied with both the PI and the FP system simultaneously. During the outside phase, the mean vGRF and the maximum vGRF determined by the FP are greater than the PI (p < 0.01). Additionally during the inside phase, the mean vGRF determined by the FP were greater than the PI (p < 0.01). During the edge changing phases, the mean vGRF determined by the FP were greater than the PI (p < 0.01). However, the minimum vGRF during the edge changing phases determined by the FP were smaller than the PI (p < 0.01) in the High-Steep skiing modes of Experts and Intermediates (p < 0.001). We have found that generally, the PI system underestimates the total vGRF compared to the FP system. However, this difference depends not only the phase in the turn (inside, outside, edge changing), but also is affected by the skier's level, the skiing mode performed and pitch. Key pointsTypically, during the steering phases of the ski turns the total vGRFs measured by the pressure-insole system were lower compared to the portable force-plate system.However, in some skiing modes during the edge changing phase, the pressure-insole system overestimates the total vGRF compared to the portable force-plate system.Differences between the forces determined by the both systems depend on the phase in the turn (inside, outside, edge changing) and are affected additionally by the skier's level, the performed skiing mode and pitch.
منابع مشابه
اثر آنی کفی طبی بر نرخ بارگذاری، ایمپالس و گشتاور آزاد در کودکان پسر دارای کف پای صاف: یک مطالعه کار آزمایی بالینی
Background and Objectives: The prevalence of flexible flat foot in children was reported between 20 -78% in previous studies. Flat foot can result into mechanical deviations in lower limb alignment during walking. The purpose of this study was to evaluate the immediate effects of medical insole on loading rate, impulse, and free moment in children with flat foot during walking. Material and M...
متن کاملComparison of ground reaction forces and the amount of load introduced during crossover landing in people with flat foot and healthy individuals
Introduction: Investigating the risk factors during single crossover landing in people with flat foot complication is unknown. Therefore, the aim of the present study is to compare the ground reaction forces and the amount of load introduced during crossover landing in people with flat foot and healthy individuals. Methods: The study method is descriptive-comparative. Twelve male subjects w...
متن کاملApplication of dGNSS in Alpine Ski Racing: Basis for Evaluating Physical Demands and Safety
External forces, such as ground reaction force or air drag acting on athletes' bodies in sports, determine the sport-specific demands on athletes' physical fitness. In order to establish appropriate physical conditioning regimes, which adequately prepare athletes for the loads and physical demands occurring in their sports and help reduce the risk of injury, sport-and/or discipline-specific kno...
متن کاملEstimating the complete ground reaction forces with pressure insoles in walking.
This study presented a method to estimate the complete ground reaction forces from pressure insoles in walking. Five male subjects performed 10 walking trials in a laboratory. The complete ground reaction forces were collected during a right foot stride by a force plate at 1000Hz. Simultaneous plantar pressure data were collected at 100Hz by a pressure insole system with 99 sensors covering the...
متن کاملValidation of Moticon’s OpenGo sensor insoles during gait, jumps, balance and cross-country skiing specific imitation movements
The purpose of this study was the experimental validation of the OpenGo sensor insole system compared to PedarX sensor insole and AMTI force-plate systems. Sixteen healthy participants performed trials in walking, running, jumping (drop and counter movement jumps), imitation drills and balance, with simultaneous measures of all three systems. Detected ground contact and flight times with OpenGo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of sports science & medicine
دوره 10 4 شماره
صفحات -
تاریخ انتشار 2011