In vivo response to cross-linked polyethylene and polycarbonate-urethane particles.
نویسندگان
چکیده
This study was undertaken to examine macrophage response to polycarbonate-urethane, a proposed alternative material to polyethylene in acetabular components of total hip arthroplasty. Polyethylene wear debris from total joint replacements has been linked to osteolysis and implant lifespan. It has been shown in vitro, that polyethylene particles cleaned of endotoxin generate less of an inflammatory cytokine response than endotoxin bound particles. Comparative particle induced effects on implant fixation were tested using endotoxin free cross-linked ultra-high molecular weight polyethylene (x-UHMWPE) and polycarbonate-urethane (PCU) particles with and without intraperitoneal injection (IP) of lipopolysaccharide (LPS) using a Ti-alloy femoral intramedullary nail rat model. MicroCT and mechanical testing assessment of peri-implant bone indicated significantly less bone and lower fixation strength, respectively, when the implant was surrounded by xUHMWPE particles compared to PCU particles (with and without LPS IP). This indicates particles of PCU may be less disruptive to bone-implant fixation than x-UHMWPE in vivo, under both LPS free and challenged conditions.
منابع مشابه
Sequentially Annealed Highly Cross-linked Polyethylene Reduced In Vivo Wear Particle Generation In TKA
Introduction: Polyethylene wear particles induce macrophages to release cytokines, which can lead to osteolysis and aseptic loosening of total joint prostheses. The generation of polyethylene wear particles is one of the most important factors that affect the midterm and long-term clinical results associated with total knee arthroplasty (TKA). Therefore, to achieve better long-term results for ...
متن کاملIn Vivo Wear Particles of Remelted Highly Cross-Linked Polyethylene in Total Hip Arthropalsty
INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...
متن کاملIn Vivo Wear Particles of Annealed Highly Cross-Linked Polyethylene in Total Hip Arthropalsty
INTRODUCTION: Polyethylene wear particles induce cytokine release by macrophage, which leads to osteolysis and aseptic loosening in total joint arthroplasties. Generation of polyethylene wear particles is one of the most important factors that affecting mid-term and long-term results of total hip arthroplasty (THA). Therefore, to reduce wear generation and to achieve better long-term results of...
متن کاملEvaluation of alternative polymer bracket materials.
INTRODUCTION Polymer brackets still have some disadvantages because of decreased wear resistance and hardness. The aim of this study was to investigate the mechanical properties of alternative bracket polymers; urethane-dimethacrylate, high-density polyethylene, and an experimental bracket polymer (EBP) consisting of polyethylene and a copolymer were tested. Polycarbonate and polyoxymethylene b...
متن کاملLong-term evaluation of a compliant cushion form acetabular bearing for hip joint replacement: a 20 million cycles wear simulation.
Soft bearing materials that aim to reproduce the tribological function of the natural joint are gaining popularity as an alternative concept to conventional hard bearing materials in the hip and knee. However, it has not been proven so far that an elastic cushion bearing can be sufficiently durable as a long term (∼20 years) articulating joint prosthesis. The use of new bearing materials should...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomedical materials research. Part A
دوره 93 1 شماره
صفحات -
تاریخ انتشار 2010