A microsurgical bifurcation rabbit model to investigate the effect of high-intensity focused ultrasound on aneurysms: a technical note

نویسندگان

  • Daniel Coluccia
  • Javier Fandino
  • Serge Marbacher
  • Salome Erhardt
  • Jenny Kienzler
  • Ernst Martin
  • Beat Werner
چکیده

BACKGROUND Recent clinical studies confirmed the high potential of MR-guided focused ultrasound (MRgFUS) in the field of functional neurosurgery. While its ability for precise thermo-ablation within soft tissue is widely recognized, the impact of high-intensity focused ultrasound (HIFU) on larger vessels is less explored. We used a bifurcation aneurysm model in rabbits to investigate the possible effects on the walls of vascular aneurysms and to assess the risk and prospect of this procedure for managing neurovascular disorders. METHODS Experimental bifurcation aneurysms were microsurgically created in New Zealand white rabbits and sonicated using MRgFUS. RESULTS A temperature of max. 54°C could be achieved close to the aneurysm, and the shape and size of the aneurysm were noticeably changed, as shown by MR angiography. CONCLUSIONS The presented rabbit model proved suitable and capable of being extended to acquire data on the effect of HIFU on aneurysms and larger vessels. The fact that HIFU led to an alteration of the aneurysm without inducing rupture encourages further investigations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microsurgical venous pouch arterial-bifurcation aneurysms in the rabbit model: technical aspects.

For ruptured human cerebral aneurysms endovascular embolization has become an equivalent alternative to aneurysm clipping.(1) However, large clinical trials have shown disappointing long-term results with unacceptable high rates of aneurysm recanalization and delayed aneurysm rupture.(2) To overcome these problems, animal experimental studies are crucial for the development of better endovascul...

متن کامل

Improved microsurgical creation of venous pouch arterial bifurcation aneurysms in rabbits.

BACKGROUND AND PURPOSE The choice of the experimental aneurysm model is essential for valid embolization-device evaluations. So far, the use of the rabbit venous pouch arterial bifurcation aneurysm model has been limited by demanding microsurgery, low aneurysm patency rates, and high mortality. This study aimed to facilitate microsurgery and to reduce mortality by optimized peri-/postoperative ...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Therapeutic effects of high intensity focused ultrasound for in patients with benign uterine tumors with regard to lifestyle and obstetric characteristics

Background: The present investigation compared the decrease in the volume of benign tumor before and after High Intensity Focused Ultrasound (HIFU) treatment to evaluate the therapeutic effects of HIFU. in terms of Lifestyle and obstetric characteristics of in patients with Benign Uterine Tumors. Materials and Methods: To collect the data on each patients’ lifestyle and obstetric characteristic...

متن کامل

Investigation on the Effect of Different Parameters in Wheeled Mobile Robot Error (TECHNICAL NOTE)

This article has focused on evaluation and identification of effective parameters in positioning performance with an odometry approach of an omni-directional mobile robot. Although there has been research in this field, but in this paper, a new approach has been proposed for mobile robot in positioning performance. With respect to experimental investigations of different parameters in omni-dire...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2014