Acute in vivo testing of an intravascular respiratory support catheter.
نویسندگان
چکیده
Current treatment for acute respiratory failure (ARF) includes the use of mechanical ventilation and/or extracorporeal membrane oxygenation, both of which can exacerbate lung injury. Intravenous respiratory support, using hollow fiber membranes placed in the vena cava, represents an attractive potential treatment for ARF, which could help reduce or eliminate ventilator induced trauma and/or other problems. Our group has been developing a respiratory support catheter (the Hattler catheter [HC]) that consists of a constrained hollow fiber bundle with a centrally located balloon. The balloon can be pulsated rapidly to increase blood flow across the fibers and decrease diffusional transfer resistance there, thus increasing gas exchange. The purpose of this study was to evaluate the HC in acute animal implants and to compare performance with that achieved in previous ex vivo studies. The HC was implanted into four calves by means of the external jugular vein and placed in the superior and inferior vena cava spanning the right atrium. Gas exchange, hemodynamics, and hematologic parameters were assessed over a range of balloon pulsation rates from 30 to 300 beats/minute. A <10% reduction in cardiac output was associated with catheter insertion and operation. The maximum CO2 exchange rate occurred at the highest pulsation rate and averaged 56 +/- 3 ml/min, or 327 +/- 15 ml/min per m2 when averaged to catheter membrane area, a level comparable to that achieved in the previous ex vivo studies. Balloon pulsation did not produce significant levels of hemolysis, as plasma-free hemoglobin remained below 10-15 mg/dl.
منابع مشابه
Antibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملAntibacterial Modification of Intravascular Catheter Surface for the Prevention of Catheter-Associated Infection
Objective: Intravascular catheter-associated infection has been increasing hospitalization in post-surgery patients mainly due to microbial colonization of the catheter surface and formation of a superficial biofilm layer. The present study is aimed in developing an effective antibacterial device which can prevent colonization of organisms by modification of catheter. Methods: In the present st...
متن کاملA Comparative Study of the Efficacy of Surfactant Administration through a Thin Intratracheal Catheter and its Administration via an Endotracheal Tube in Neonatal Respiratory Distress Syndrome
Background: The cornerstone of the treatment of respiratory distress syndrome (RDS) is respiratory support and surfactant replacement therapy. The administration of surfactant through a thin intratracheal catheter is one of the methods used to reduce one of the standard technique complications of a surfactant injection (Intubation-Surfactant-Extubation method [INSURE]). The aim of this study wa...
متن کاملReview of recommendations to prevent and reduce catheter-related bloodstream infections
ABSTRACT Aim. We sought to review studies regarding interventions to prevent or reduce catheter-related bloodstream infections (CRBSIs). Background. CRBSIs are associated with peripheral and central intravenous catheters, including nontunneled central catheters, tunneled central catheters, peripherally inserted central venous catheters (PICC), totally implanted intravascular access devices (por...
متن کاملCatheter-related superior vena cava syndrome complicated by chylothorax in a premature infant.
A premature infant experienced respiratory distress due to chylothorax. Contrast-enhanced chest computed tomography showed superior vena cava (SVC) obstruction with collaterals, and surgery confirmed an obstruction of the SVC by intravascular fibrotic tissue and thrombi caused by placement of a central venous catheter. The respiratory distress improved after surgical intervention. In the differ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- ASAIO journal
دوره 47 5 شماره
صفحات -
تاریخ انتشار 2001