The Response Function of Isocart (ortec) Gamma-ray Spectrometry System Using Monte Carlo Simulations

نویسندگان

  • DANIELA GURAU
  • OCTAVIAN SIMA
چکیده

The routine operation and maintenance of nuclear facilities generate quantities of radioactive material in many different matrices that are packed in many different sized containers. The waste is often packaged in large containers, such as 220 l drums, because process operators find drums more economical to handle than small containers. Based on regulations, the radioactivity and the radionuclide composition of the waste should be characterized before moving, shipping offsite, burying, or placing in a storage area. The most important step of the characterization process, establishing radionuclide content, is often achieved by nondestructive assay (NDA). In this work calculation techniques useful for the calibration and evaluation of measurements of radioactive waste drums by gamma-ray spectrometry were developed. To this end, a simulation program based on GEANT 3.21 toolkit was developed to simulate the response function of ISOCART gamma-ray spectrometry system for a geometry measurement with the drum volume divided in 40 volume elements. The Monte Carlo method was applied to obtain the expected spectra in the energy range from 50 to 2000 keV, the full energy peak efficiencies and the total efficiencies for sources uniformly distributed in each of the volume elements defined within the drum as well as for the source uniformly distributed in the entire drum.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dedicated Monte Carlo Procedures Applied in Gamma- ray Spectrometry Used in Decommissioning of Nuclear Facilities

Because the experimental efficiency calibration is limited to several measurement geometries and cannot be applied directly to all measurement configurations, the efficiency transfer method for the efficiency computation was applied using ETNA software. An approach using efficiencies measured with point sources combined with theoretical procedures was applied for obtaining the peak efficiency ε...

متن کامل

Planar and SPECT Monte Carlo acceleration using a variance reduction technique in I131 imaging

Background: Various variance reduction techniques such as forced detection (FD) have been implemented in Monte Carlo (MC) simulation of nuclear medicine in an effort to decrease the simulation time while keeping accuracy. However most of these techniques still result in very long MC simulation times for being implemented into routine use. Materials and Methods: Convolution-based force...

متن کامل

Monte Carlo Evaluation of Gamma Knife Dose Profile in Real Brain Phantom

Introduction The Gamma Knife system is designed solely for non-invasive treatment of brain disorders, and it benefits from stereotactic surgical techniques. Dose calculations required in the system are performed by GammaPlan code; in this code, brain tissue is considered uniform. In the present study, we evaluated the effect of Gamma Knife system on the obtained dose through simulating a real ...

متن کامل

Design of Light Multi-layered Shields for Use in Diagnostic Radiology and Nuclear Medicine via MCNP5 Monte Carlo Code

Introduction Lead-based shields are the most widely used attenuators in X-ray and gamma ray fields. The heavy weight, toxicity and corrosion of lead have led researchers towards the development of non-lead shields. Materials and Methods The purpose of this study was to design multi-layered shields for protection against X-rays and gamma rays in diagnostic radiology and nuclear medicine. In this...

متن کامل

Bremsstrahlung imaging from the liver using the Monte Carlo simulation

Introduction: Most beta and gamma radiation radioisotopes used for treatment are not suitable for imaging. The bremsstrahlung images on a conventional gamma camera helped to localize the radionuclide within and outside of the lesion. Secondary scattering of gamma rays of higher energy and bremsstrahlung causes contamination in the energy window and reducing the contrast and resolution of the im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012