Optimizing refractive lens exchange with bimanual microincision phacoemulsification.

نویسندگان

  • I Howard Fine
  • Richard S Hoffman
  • Mark Packer
چکیده

Bimanual microincision phacoemulsification entails the removal of the crystalline lens through 2 1.2 mm incisions. Infusion is provided through a separate irrigating handpiece, and phacoemulsification and aspiration are performed through a sleeveless phacoemulsification needle. We describe a technique for refractive lens exchange using bimanual microincision phacoemulsification. Capsulorhexis formation, cortical cleaving hydrodissection, lens extraction in the iris plane, and residual cortex removal are performed through the microincisions. This technique offers improved surgeon control throughout the procedure and added safety by maintaining continuous pressurization of the eye while removing the lens far from the posterior capsule.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraocular pressure during phacoemulsification.

PURPOSE To assess changes in intraocular pressure (IOP) during standard coaxial or bimanual microincision phacoemulsification. SETTING Oregon Eye Center, Eugene, Oregon, USA. METHODS Bimanual microincision phacoemulsification (microphaco) was performed in 3 cadaver eyes, and standard coaxial phacoemulsification was performed in 1 cadaver eye. A pressure transducer placed in the vitreous cav...

متن کامل

Prospective randomized trial of limbal relaxing incisions combined with microincision cataract surgery.

PURPOSE To evaluate clinical outcomes of limbal relaxing incision (LRI) combined with bimanual phacoemulsification and insertion of an intraocular lens (IOL) developed for bimanual microincision cataract surgery (MICS). METHODS In a prospective, single-center study, eyes with > or = 0.75 diopters (D) of keratometric astigmatism were randomly assigned to two surgical techniques: 1) bimanual MI...

متن کامل

Refractive lens surgery.

This article compares methods of axial length measurement for determining intraocular lens power and describes bimanual micro incision phacoemulsification for refractive lens exchange and routine cataract surgery, which offers an enormous advantage of maintaining a more stable intraocular environment during lens removal. This advantage may be especially important in high myopes who are at a gre...

متن کامل

Evaluation of early corneal endothelial cell loss in bimanual microincision cataract surgery (MICS) in comparison with standard phacoemulsification.

PURPOSE To analyze early corneal endothelial cell loss due to microincision cataract surgery (MICS) in comparison with standard phacoemulsification through the temporal clear corneal incision. METHODS The examined group consisted of a nonrandomized, consecutive prospective series of 20 eyes of 20 patients who underwent uneventful microincision cataract surgery. Twenty eyes of 20 patients who ...

متن کامل

Visual and Refractive Results of Cataract Surgery by Phacoemulsification Method in Patients with Keratoconus

Purpose: To examine the visual and refractive results of cataract surgery by phacoemulsification method in patients with keratoconus. Methods: In this retrospective study, the files of patients with keratoconus, who underwent phacoemulsification between 2008 and 2017, were evaluated. The intraocular lens power calculation formula was SRK/T. Post-operative visual and refractive results were anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 30 3  شماره 

صفحات  -

تاریخ انتشار 2004