Short echo time in vivo prostate ¹H-MRSI.

نویسندگان

  • Niranjan Venugopal
  • Boyd McCurdy
  • Salem Al Mehairi
  • Aziz Alamri
  • Gurdarshan S Sandhu
  • Sri Sivalingam
  • Darrel Drachenberg
  • Lawrence Ryner
چکیده

Visualization of short echo time (TE) metabolites in prostate magnetic resonance spectroscopic imaging is difficult due to lipid contamination and pulse timing constraints. In this work, we present a modified pulse sequence to permit short echo time (TE=40ms) acquisitions with reduced lipid contamination for the detection of short TE metabolites. The modified pulse sequence employs the conformal voxel MRS (CV-MRS) technique, which automatically optimizes the placement of spatial saturation planes to adapt the excitation volume to the shape of the prostate, thus reducing lipid contamination in prostate magnetic resonance spectroscopic imaging (MRSI). Metabolites were measured and assessed using a modified version of LCModel for analysis of in vivo prostate spectra. We demonstrate the feasibility of acquiring high quality spectra at short TEs, and show the measurement of short TE metabolites, myo-inositol, scyllo-inositol, taurine and glutamine/glutamate for both single and multi-voxel acquisitions. In single voxels experiments, the reduction in TE resulted in 57% improvement in the signal-to-noise ratio (SNR). Additional 3D MRSI experiments comparing short (TE=40 ms), and long (TE=130 ms) TE acquisitions revealed a 35% improvement in the number of adequately fitted metabolite peaks (775 voxels over all subjects). This resulted in a 42 ± 24% relative improvement in the number of voxels with detectable citrate that were well-fitted using LCmodel. In this study, we demonstrate that high quality prostate spectra can be obtained by reducing the TE to 40 ms to detect short T2 metabolites, while maintaining positive signal intensity of the spin-coupled citrate multiplet and managing lipid suppression.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-speed 3T MR spectroscopic imaging of prostate with flyback echo-planar encoding.

Prostate MR spectroscopic imaging (MRSI) at 3T may provide two-fold higher spatial resolution over 1.5T, but this can result in longer acquisition times to cover the entire gland using conventional phase-encoding. In this study, flyback echo-planar readout trajectories were incorporated into a Malcolm Levitt's composite-pulse decoupling sequence (MLEV)-point-resolved spectroscopy sequence (PRES...

متن کامل

Optimal timing for in vivo 1H-MR spectroscopic imaging of the human prostate at 3T.

Proton MR spectroscopic imaging ((1)H-MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectroscopic imaging of the human prostate at 3T. For in vivo detection of the strongly coupled spin system of citra...

متن کامل

(1)H MR spectroscopic imaging of the prostate at 7T using spectral-spatial pulses.

PURPOSE To assess the feasibility of prostate (1)H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously. METHODS A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate (1)H-MRSI at 7T was performed with th...

متن کامل

Hyperpolarized C-13 spectroscopic imaging of the TRAMP mouse at 3T-initial experience.

The transgenic adenocarcinoma of mouse prostate (TRAMP) mouse is a well-studied murine model of prostate cancer with histopathology and disease progression that mimic the human disease. To investigate differences in cellular bioenergetics between normal prostate epithelial cells and prostate tumor cells, in vivo MR spectroscopic (MRS) studies with non-proton nuclei, such as (13)C, in the TRAMP ...

متن کامل

Optimal Timing for In Vivo H-MR Spectroscopic Imaging of the Human Prostate at 3T

Proton MR spectroscopic imaging (H-MRSI) of the human prostate, which has an interesting clinical potential, may be improved by increasing the magnetic field strength from 1.5T to 3T. Both theoretical and practical considerations are necessary to optimize the pulse timing for spectroscopic imaging of the human prostate at 3T. For in vivo detection of the strongly coupled spin system of citrate,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2012