Intravascular ultrasound correlates of corrected TIMI framecount.

نویسندگان

  • Nihal Ozdemir
  • Cihangir Kaymaz
  • Cevat Kirma
  • Murat Akçay
  • Murat Yüce
  • Fikret Turan
  • Mehmet Ozkan
چکیده

The TIMI frame count (TFC) is an index of coronary blood flow, and a correction in TFC (CTFC) for left anterior descending artery (LAD) has also been proposed. However, the relationship between TFC and intravascular ultrasound (IVUS) parameters of culprit coronary arteries has not been reported. The aim of this study was to investigate IVUS-derived correlates of TFC before and after stenting, and to assess the validation of its correction for LAD. The study population was comprised of 38 patients with acute coronary syndrome or stable coronary artery disease studied by IVUS before and after stenting (LAD 21, circumflex 8, right coronary artery 9). For LAD, CTFC was calculated by dividing the TFC by 1.7. Preintervention luminal % area stenosis was 82 +/- 12.3%. Pre- and postintervention target lesion lumen areas were 1.8 +/- 0.5 mm2 and 8.5 +/- 0.5 mm2 (P<0.0001), and CTFC were 35.3 +/- 16.8 and 16.9 +/- 4.3 (P<0.0001), respectively. In the 76 IVUS studies, CTFC showed a good correlation to luminal % area stenosis (r = 0.69, P<0.001), and a good and negative correlation to target lesion lumen area (r = -0.70, P<0.001). Postprocedural improvement in CTFC showed a modest correlation to acute lumen gain (r = 0.5, P<0.05). With respect to culprit arteries, pre and postintervention IVUS parameters and CTFC, and net CTFC change after stenting were not different (P>0.05). However, uncorrected TFC of LAD was significantly higher than both the CTFC of LAD and TFC of the other two coronary arteries (P<0.05). We conclude that CTFC is closely correlated to target lesion luminal area and luminal % area stenosis whereas a modest correlation is present between improvement in CTFC and acute luminal gain due to stenting. Results from different coronary arteries with comparable IVUS parameters seem to support the validity of a correction in TFC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical significance of echo signal attenuation on intravascular ultrasound in patients with coronary artery disease.

BACKGROUND Atherosclerotic plaque that shows echo signal attenuation (EA) without associated bright echoes is sometimes observed by intravascular ultrasound but its clinical significance remains unclear. We investigated the impact of EA on coronary perfusion and evaluated the pathological features of plaque with EA. METHODS AND RESULTS We studied 687 native coronary lesions in 687 consecutive...

متن کامل

Intravascular Ultrasound Observation of the Mechanism of No-Reflow Phenomenon in Acute Myocardial Infarction

OBJECTIVE To study the mechanism of the no-reflow phenomenon using coronary angiography (CAG) and intravascular ultrasound (IVUS). METHODS A total of 120 patients with acute myocardial infarction (AMI) who successfully underwent indwelling intracoronary stent placement by percutaneous coronary intervention (PCI). All patients underwent pre- and post-PCI CAG and pre-IVUS. No-reflow was defined...

متن کامل

ایمنی، اثربخشی و هزینه اثربخشی فناوری تصویربرداری داخل عروقی در مقایسه با آنژیوگرافی در مداخلات عروق کرونر : ارزیابی سریع فناوری سلامت

Background: Intravascular imaging is a tool to detect coronary artery atherosclerosis which plays the major role in vessel stenosis degree determination and plaque pathology as a supplement of invasive angiography. This study aimed at comparing Intravascular imaging with invasive angiography. Materials and Methods: For retrieving second type studies, PubMed, Cochrane Library and Centre for R...

متن کامل

Is the corrected TIMI frame count an independent predictor of adverse outcome?

Independent Predictor of Adverse Outcome? To the Editor: The corrected TIMI frame count (cTFC) has evolved into a standard measurement in many angiographic core laboratories. Although the reproducibility of the cTFC has been demonstrated,1,2 its superiority to TIMI flow grading has remained in question. Work done in our core laboratory has not found the cTFC to have predictive value independent...

متن کامل

Successful stenting with optical frequency domain imaging guidance for spontaneous coronary artery dissection.

A 51-year-old woman was urgently admitted because of chest pain. Emergent coronary angiography revealed diffuse stenosis from the proximal to distal portion of the right coronary artery (RCA) with Thrombolysis In Myocardial Infarction (TIMI) flow grade 2 (Figure 1). No stenosis was seen in the left coronary artery. Intravascular ultrasound (IVUS) images revealed an intracoronary hematoma from t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese heart journal

دوره 44 2  شماره 

صفحات  -

تاریخ انتشار 2003