Accuracy and Precision of an Accelerometer-Based Smartphone App Designed to Monitor and Record Angular Movement over Time.

نویسندگان

  • Adam J Bittel
  • Ashraf Elazzazi
  • Daniel C Bittel
چکیده

BACKGROUND Therapeutic exercise is a central component in the management of many common conditions. It is imperative, therefore, that clinicians monitor and correct patient performance to facilitate the use of proper form both in the clinic and during home exercise programs. Although clinicians are trained to prescribe exercise and analyze form, there are many subtleties that may be missed by relying on visual assessment. This study investigated the accuracy and precision of a novel, exercise-training smartphone application (app), running on an iPhone(®) (Apple, Cupertino, CA) 4 and using its LIS331DLH accelerometer to dynamically measure and record movement during exercise. MATERIALS AND METHODS The iPhone, running the app, was mounted to the movement arm of a Biodex™ isokinetic dynamometer System 4 (Biodex Corp., Shirley, NY). Angle and time measurements taken by the app were compared with the dynamometer (gold standard) while rotating at 30°/s, 60°/s, 90°/s, 120°/s, and 150°/s. Accuracy was assessed using limits of agreement and fast Fourier transform analyses. Precision was assessed using the coefficient of variation. RESULTS The mean difference between the app and the Biodex recordings was less than 1°/s for all test velocities. The coefficient of variation was less than 3% at velocities from 30°/s to 120°/s and less than 7% at 150°/s. CONCLUSIONS The app was highly accurate and precise. The validation of apps designed for motion tracking is a vital prerequisite to clinical implementation. The app described in this article is clinically identical to the Biodex dynamometer in its ability to accurately and precisely read angular movement over time.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of the Effective Components in the PDR Positioning Method Based on Detecting the User’s Movement Mode Using Smartphone Sensors

The purpose of this paper is to evaluate and improve the accuracy of indoor positioning using smartphone sensors based on Pedestrian Dead Reckoning (PDR) method. In some specific situations, such as fires or power outages that disable infrastructure-based positioning techniques, using PDR method based on smartphone sensors that perform positioning continuously is a good solution.This paper focu...

متن کامل

Identifying Educational Contents and Technical Features of a Self-Management Smartphone Application for Women with Breast Cancer

Background and Objective: Breast cancer patients need a variety of skills and abilities to deal with the consequences of the illness. Self-management is one of the operational strategies that leads to disease acceptance, treatment adherence, and improving the quality of life. The use of smartphone applications (apps) can play a pivotal role in the support and self-management of breast cancer pa...

متن کامل

Review and Comparison of In-field Calibration Methods of Accelerometer Based on Gravity Vector

Considering the wide applications of accelerometers to determine position and attitude and due to reducing of accuracy of this sensors because of some errors, this paper discusses the calibration of accelerometers. Also because the traditional calibration methods are very time consuming, costly and need precision laboratory equipment, in-field calibration methods are recommended which are simpl...

متن کامل

Smartphone-based application for training outpatient cardiac rehabilitation: Design and usability evaluation

Introduction: Due to the increasing trend of heart diseases and their complications, programs such as cardiac rehabilitation can reduce the complications and faster recovery of patients. Therefore, the aim of this study was to design and evaluate the usability of smartphone-based application for training outpatient cardiac rehabilitation. Materials and Methods: This applied-developmental study ...

متن کامل

Ways to increase precision and accuracy of wound area measurement using smart devices: Advanced app Planimator

INTRODUCTION Wound surface area measurement is important as therapeutic decisions may depend on the change of wound surface area over time. Digital planimetry is a popular technique in wound area measurement. It is accurate and repeatable when calibration is performed with 2 rulers placed at opposite sides of a wound. The aim of the current study was improving accuracy and precision of wound ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Telemedicine journal and e-health : the official journal of the American Telemedicine Association

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 2016