Physical, morphological and dosimetric characterization of the Teflon agglutinator to thermoluminescent dosimetry

نویسنده

  • M. I. Teixeira
چکیده

In preparing of thermoluminescent dosimeters (TLD) it is common to use as agglutinator the polytetrafluoroethylene (PTFE), called Teflon. In this paper the physical, morphological and dosimetric characteristics of Teflon were evaluated aiming its application in thermoluminescent dosimetry. The differential thermal analysis (DTA) and thermogravimetry (TG) results showed that the Teflon glass transition and melting points are of about 48 1C and 340 1C, respectively. By means of the X-ray diffraction technique, the crystallinity index Kc was estimated as 94%. Micrographs of Scanning Electron Microscopy (SEM) showed a cohesive surface in spodumene–Teflon pellets, as required for thermoluminescent dosimeters (TLD), leading to the conclusion that Teflon acts as binder, providing greater mechanical resistance to the TL pellets. However, Teflon may influence high doses dosimetry when it is applied as an agglutinator. Preliminary results of Teflon pellets dosimetric properties, with their dose– response curve between 50 Gy and 60 kGy, TL response reproducibility and minimum detectable dose, indicate the possibility of use of pure Teflon TLD in high-dose dosimetry. & 2012 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric characterization of a high dose rate 192I source for brachytherapy application using Monte Carlo simulation and benchmarking with thermoluminescent dosimetry

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

متن کامل

In vivo dosimetry with thermoluminescent dosimeters in external photon beam radiotherapy.

The ultimate check of the actual dose delivered to a patient in radiotherapy can only be achieved by using in vivo dosimetry. This work reports a pilot study to test the applicability of a thermoluminescent dosimetric system for performing in vivo entrance dose measurements in external photon beam radiotherapy. The measurements demonstrated the value of thermoluminescent dosimetry as a treatmen...

متن کامل

Influence of thermal treatments on the response of sand radiation detectors for high-dose dosimetry.

The dosimetric properties of sand from Brazilian beaches have shown to be useful for high-dose dosimetry. The thermoluminescent (TL) and electron paramagnetic resonance (EPR) techniques were utilised, and the sand samples were recently studied in relation to their main dosimetric properties. The EPR signal at g = 1.999 grows significantly in function of the absorbed dose, and the TL peaks appea...

متن کامل

Study on the response of indigenously developed CaSO4:Dy phosphor-based neutron dosemeter.

In the present paper, we report the indigenous development of a neutron-sensitive thermoluminescent dosemeter (TLD) based on CaSO4:Dy Teflon TL disc. The study includes indigenous development of a neutron dosemeter and its response in terms of operational quantity to different energies of neutrons under various irradiation conditions. It was found that the thermal neutron sensitivity of the CaS...

متن کامل

Assessment of basic physical and dosimetric parameters of synthetic single-crystal diamond detector and its use in Leksell Gamma Knife and CyberKnife small radiosurgical fields

Background: To determine the basic physical and dosimetric properties of a new synthetic single-crystal diamond detector and its application for relative small field dosimetry. Materials and Methods: The pre-irradiation dose required to stabilize detector response, dose rate dependence, photon and electron energy dependence, temperature dependence and angular dependence of MicroDiamond detector...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012