Scanning electron microscopy and energy dispersive spectroscopy findings in explanted PMMA and hydrophilic acrylic intraocular lenses.

نویسنده

  • H Gungel
چکیده

PURPOSE To investigate the presence of calcium (Ca) aggregates influencing biocompatibility and the factors that affect calcium accumulation in explanted intraocular lenses (IOL) and to analyze the Ca distribution in an opacified hydrophilic acrylic lens. METHODS Surface irregularities and aggregates of 13 IOLs were studied with scanning electron microscopy, and their relative concentrations with energy dispersive spectroscopy (EDS). Relationships of distribution between Ca and silicone (Si) and nitrogen (N) and between N and Si and Na, and the influence of Si on Ca accumulation and the effect of differences in lens material on the distribution of N, and the effect of endophthalmitis on the distribution of Ca were evaluated statistically. EDS analyses were performed on the surface and cross-section of the opacified lens. RESULTS The statistically significant relationships between the distribution of Ca and N, and between the distribution of N and Na, the significant effect of Si on the Ca accumulation, significant relationship between endophthalmitis and the Ca accumulation in the aggregates were shown. The EDS analysis of the opacified IOL, Ca and P peaks were shown from the whole surface, Ca, O peaks were determined from cross-sections over a 70-80 mum distance. CONCLUSIONS In the aggregates influencing IOL biocompatibility, presence of proteins was determined to be more important than the presence of Si regarding the distribution of Ca, while the presence of Si affected the accumulation of Ca. Opacification, caused by the Ca accumulation within the lens, was found to result from Ca penetrating from lens pores.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Postoperative opacification of polymethylmethacrylate- intraocular lens

Background: Opacification of ophthalmic devices has been previously reported in silicone scleral buckle, Molteno implant, and intraocular lens opacification. However, there is no report on polymethyl methacrylate (PMMA) intraocular lens (IOL) calcification. Objective: Report the clinical feature, histopathologic and spectrophotometer analysis of opacified three-piece PMMA IOL. Method: A 60-year...

متن کامل

Hydrophilic intraocular lens opacification after posterior lamellar keratoplasty - a material analysis with special reference to optical quality assessment

BACKGROUND Laboratory analysis and optical quality assessment of explanted hydrophilic intraocular lenses (IOLs) with clinically significant opacification after posterior lamellar keratoplasty (DMEK and DSAEK). METHODS Thirteen opacified IOLs after posterior lamellar keratoplasty, 8 after descemet stripping automated endothelial keratoplasty (DSAEK), 3 after descemet membrane endothelial kera...

متن کامل

Bacterial adherence of Staphylococcus epidermidis to intraocular lenses: a bioluminescence and scanning electron microscopy study.

PURPOSE To analyze and compare the adherence of Staphylococcus epidermidis to intraocular lenses (IOLs) made of five different biomaterials (native or heparinized polymethylmethacrylate, silicone, hydrophilic acrylic, or hydrogel) and to detail the different steps and mechanisms of bacterial adhesion to a polymer. METHODS A clinical strain carrying the intercellular adhesion (ica) locus was u...

متن کامل

Comparison of Biofilm Formation Capacities of Two Clinical Isolates of Staphylococcus Epidermidis with and without icaA and icaD Genes on Intraocular Lenses

OBJECTIVES To compare biofilm formations of two Staphylococcus epidermidis (S. epidermidis) isolates with known biofilm formation capacities on four different intraocular lenses (IOL) that have not been studied before. MATERIALS AND METHODS Two isolates obtained from ocular surfaces and identified in previous studies and stored at -86 °C in 15% glycerol in the microbiology laboratory of the A...

متن کامل

Anterior Segment Intraocular Lens Edge Profiles of Currently Available Intraocular Lenses and Recent Improvements

We evaluated the microstructure of the edges of currently available foldable intraocular lenses (IOLs). The methodology used assisted an IOL manufacturer (Hoya, Japan) to optimise the edge profile of its lenses. Ten designs of hydrophobic acrylic, six designs of silicone and 24 designs of hydrophilic acrylic IOLs were imaged under scanning electron microscopy (SEM), and the photographs were imp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2009