High-Resolution Differential Phase Contrast Imaging Using Microfocus X-Ray Sources
نویسندگان
چکیده
We combined grating-based phase contrast imaging with projection magnification using a high-brilliance microfocus x-ray source. This geometry offers increased detection efficiency even at higher energies for quantitative high-resolution phase contrast imaging. By systematic methodical investigations, it is shown, how the primary measurement signal is affected by the magnification factor. Furthermore, the influences of different physical parameters, as the size or the energy spectrum of the x-ray source, on the measurement results are discussed using numerical simulations. Based on these investigations, the phase shift can be determined quantitatively with high precision. Finally, experimental results demonstrate feasible applications like quality inspection of refractive x-ray lenses and high-resolution phase contrast tomography.
منابع مشابه
Phase-contrast x-ray imaging with a liquid-metal-jet-anode microfocus source
Phase-contrast methods increase contrast, detail, and selectivity in x-ray imaging. Present compact x-ray sources do not provide the necessary spatial coherence with sufficient power to allow the laboratory-scale high-resolution phase-contrast imaging with adequate exposure times. In this letter, the authors demonstrate phase-contrast imaging with few-micron detail employing a compact 6.5 m spo...
متن کاملProcessing of projections containing phase contrast in laboratory micro-computerized tomography imaging
Free-space-propagation-based imaging belongs to several techniques for achieving phase contrast in the hard X-ray range. The basic precondition is to use an X-ray beam with a high degree of coherence. Although the best sources of coherent X-rays are synchrotrons, spatially coherent X-rays emitted from a sufficiently small spot of laboratory microfocus or sub-microfocus sources allow the transfe...
متن کاملFirst application of liquid-metal-jet sources for small-animal imaging: high-resolution CT and phase-contrast tumor demarcation.
PURPOSE Small-animal studies require images with high spatial resolution and high contrast due to the small scale of the structures. X-ray imaging systems for small animals are often limited by the microfocus source. Here, the authors investigate the applicability of liquid-metal-jet x-ray sources for such high-resolution small-animal imaging, both in tomography based on absorption and in soft-...
متن کاملComparison of two x-ray phase-contrast imaging methods with a microfocus source.
We present a comparison for high-resolution imaging with a laboratory source between grating-based (GBI) and propagation-based (PBI) x-ray phase-contrast imaging. The comparison is done through simulations and experiments using a liquid-metal-jet x-ray microfocus source. Radiation doses required for detection in projection images are simulated as a function of the diameter of a cylindrical samp...
متن کاملFactors Affecting In-line Phase Contrast Imaging with a Laboratory Microfocus X-ray Source
An in-line method of phase contrast imaging is investigated using a polychromatic laboratorybased microfocus X-ray source. The effect of source size is considered, and by introducing water into the imaging path the influence of water on the phase contrast is determined. The results confirm that good phase contrast images can be achieved using a polychromatic laboratory-based X-ray source, and d...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007