Systolic Blood Pressure Accuracy Enhancement in the Electronic Palpation Method Using Pulse Waveform

نویسندگان

  • H. S. S. Sorvoja
  • R. A. Myllylä
  • S. M. Nissilä
  • P. M. Kärjä-Koskenkari
  • J. K. Koskenkari
  • M. K. Lilja
  • Y A. Kesäniemi
چکیده

This paper presents and evaluates some methods to improve the accuracy of systolic blood pressure measurements based on pulse waveform. A set of measurement was carried out with elderly cardiac surgery patients. The experiments comprised two to five measurements per patient, each including a one-minute follow-up, after which the cuff was slowly inflated over the systolic blood pressure. Systolic pressure errors were defined and correlations with other specific values, like pressure rise time, pulse wave velocity, systolic pressure, augmentation, arm circumference and body mass index were calculated. These indices may be affected by arterial stiffness, a common source of errors in blood pressure measurements. With a value of –0.52, the character which correlated best with systolic error was found to be the peak level of the first derivative of the pressure signal. Also rise time (10%...90%) exhibits a moderate correlation, +0.49. On the other hand, pulse wave velocity, body mass index, cardiac output, peripheral and intra-arterial temperature do not seem to correlate with systolic blood pressure error. It is also noteworthy that indices describing the rising edge of the pressure pulse correlated better with systolic pressure error than those describing the falling part. Using the first derivative peak level method, accuracy improved slightly.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing and Constructing an Optical System to measure Continuous and Cuffless Blood Pressure Using Two Pulse Signals

Introduction Blood pressure (BP) is one of the important vital signs that need to be monitored for personal healthcare. Arterial blood pressure is estimated from pulse transit time (PTT). This study uses two pulse sensors to get PTT. The aim of this study was to construct an optical system and to monitor blood pressure continuously and without cuff in people with different ages. Materials and M...

متن کامل

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Continuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

متن کامل

Arterial and plethysmographic waveform analysis in anesthetized patients with hypovolemia.

BACKGROUND Respiratory-induced arterial and plethysmographic (pulse oximetry) waveform changes were shown to be good predictors of cardiac output response to increased preload. The aim of this study was to evaluate the reliability of arterial and plethysmographic waveform variables in patients with mild hypovolemia. METHODS Patients undergoing autologous hemodilution were studied. After anest...

متن کامل

A Method to Determine Diastolic Blood Pressure Based on Pressure Pulse Propagation in the Electronic Palpation Method

This paper evaluates the accuracy of the pulse transit time method for determining diastolic blood pressure using intra-arterial blood pressure as a reference. First, the paper describes the method. Then it discusses two sets of measurements which were carried out to determine the accuracy of the method with cardiac operated patients and healthy young volunteers. The thus obtained accuracies we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001