Optical resolution of phase measurements of laser Fizeau interferometer
نویسندگان
چکیده
Accurate interferometric measurement of large laser slabs requires spatial frequencies of 1mm/cycle to 33mm/cycle over a 100mm field of view to be passed by the system with no more than 25%loss in modulation. To eliminate noise and artifacts due to strictly coherent imaging, many commercial interferometers employ a rotating diffuser on an intermediate image plane and relay this image incoherently onto a detector. Unfortunately, this process may adversely affect the resolution of the instrument. Through measurement of a sinusoidal phase grating an fused silica step, the transfer function a laser Fizeau interferometer was measured for both a system with and without the incoherent relay system. Results are compared to those predicted by diffraction theory. Studies of the effects of defocus and propagation on the measurement were also made. Using strictly coherent imaging dramatically increases the system's ability to measure features of high spatial frequency and allows the measurement requirements for laser slabs to be met.
منابع مشابه
Errors Caused by Nearly Parallel Optical Elements in a Laser Fizeau Interferometer Utilizing Strictly Coherent Imaging
Most commercial laser Fizeau interferometers employ a rotating diffuser on an intermediate image plane. The image formed on this plane is relayed to the detector using incoherent imaging, eliminating potential interference effects from elements after the diffuser. Systems requiring high spatial frequency resolution cannot employ the diffuser or incoherent relay system to the degradation they ca...
متن کاملComparison of a Liquid Crystal Point-Diffraction Interferometer and a Commercial Phase-Shifting Interferometer
142 LLE Review, Volume 83 Introduction Fusion-class lasers, such as OMEGA, typically require hundreds, or even thousands, of high-performance optical elements ranging in diameter from several millimeters to tens of centimeters. To obtain high irradiation uniformity required for direct-drive ICF, it is critical that (1) the optical performance of these elements and associated optical subsystems ...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملFizeau interferometer for measurement of plasma electron current
A high-resolution, vertically viewing far-infrared polarimeter-interferometer system is currently used on the Madison symmetric torus (MST) reversed-field pinch (RFP) to measure the plasma electron density and toroidal current density via Faraday rotation. In this article, we propose a scheme to measure the well-known Fizeau effect, whereby through modest modification of the existing apparatus,...
متن کاملTransfer function characterization of laser Fizeau interferometer for high spatial frequency phase measurements
Large, high power laser systems such as that being constructed by Lawrence Livermore National Laboratories for the National Ignition Facility (NIF) require accurate measurement of spatial frequencies of up to 2.5lines/mm over a 100mm field of view. In order to ensure accurate measurements of the parts, the test apparatus must be well characterized. The system transfer function (SiT) of the inte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005