Long-term storage and impedance-based water toxicity testing capabilities of fluidic biochips seeded with RTgill-W1 cells.
نویسندگان
چکیده
Rainbow trout gill epithelial cells (RTgill-W1) are used in a cell-based biosensor that can respond within one hour to toxic chemicals that have the potential to contaminate drinking water supplies. RTgill-W1 cells seeded on enclosed fluidic biochips and monitored using electric cell-substrate impedance sensing (ECIS) technology responded to 18 out of the 18 toxic chemicals tested within one hour of exposure. Nine of these chemical responses were within established concentration ranges specified by the U.S. Army for comparison of toxicity sensors for field application. The RTgill-W1 cells remain viable on the biochips at ambient carbon dioxide levels at 6°C for 78weeks without media changes. RTgill-W1 biochips stored in this manner were challenged with 9.4μM sodium pentachlorophenate (PCP), a benchmark toxicant, and impedance responses were significant (p<0.001) for all storage times tested. This poikilothermic cell line has toxicant sensitivity comparable to a mammalian cell line (bovine lung microvessel endothelial cells (BLMVECs)) that was tested on fluidic biochips with the same chemicals. In order to remain viable, the BLMVEC biochips required media replenishments 3 times per week while being maintained at 37°C. The ability of RTgill-W1 biochips to maintain monolayer integrity without media replenishments for 78weeks, combined with their chemical sensitivity and rapid response time, make them excellent candidates for use in low cost, maintenance-free field-portable biosensors.
منابع مشابه
Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity.
This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity...
متن کاملA portable cell-based impedance sensor for toxicity testing of drinking water.
A major limitation to using mammalian cell-based biosensors for field testing of drinking water samples is the difficulty of maintaining cell viability and sterility without an on-site cell culture facility. This paper describes a portable automated bench-top mammalian cell-based toxicity sensor that incorporates enclosed fluidic biochips containing endothelial cells monitored by Electric Cell-...
متن کاملEvaluation and refinement of a field-portable drinking water toxicity sensor utilizing electric cell-substrate impedance sensing and a fluidic biochip.
The US Army's need for a reliable and field-portable drinking water toxicity sensor was the catalyst for the development and evaluation of an electric cell-substrate impedance sensing (ECIS) device. Water testing technologies currently available to soldiers in the field are analyte-specific and have limited capabilities to detect broad-based water toxicity. The ECIS sensor described here uses r...
متن کاملSuitability of invertebrate and vertebrate cells in a portable impedance-based toxicity sensor: temperature mediated impacts on long-term survival.
Using ECIS (electric cell-substrate impedance sensing) to monitor the impedance of vertebrate cell monolayers provides a sensitive measure of toxicity for a wide range of chemical toxicants. One major limitation to using a cell-based sensor for chemical toxicant detection in the field is the difficulty in maintaining cell viability over extended periods of time prior to use. This research was p...
متن کاملInteraction of Silver Nanoparticles (AgNP) with Rainbow Trout Gill Cell Lines
VIII and showed the weakest protection by silver ligands. This revealed that AgNP seem to particularly affect RTgill-W1 cell lysosomes. To shed light on the path of AgNP in cells leading to toxicity, AgNP uptake by the cells was explored on exposure in d-L15/ex medium. Quantification of silver associated with cells indicated that RTgillW1 cells took up AgNP in a more efficient way than AgNO3. E...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Toxicology in vitro : an international journal published in association with BIBRA
دوره 26 5 شماره
صفحات -
تاریخ انتشار 2012