An Oriented Flux Symmetry Based Active Contour Model for Three Dimensional Vessel Segmentation

نویسندگان

  • Max W. K. Law
  • Albert C. S. Chung
چکیده

This paper proposes a novel approach to segment three dimensional curvilinear structures, particularly vessels in angiography, by inspecting the symmetry of image gradients. The proposed method stresses the importance of simultaneously considering both the gradient symmetry with respect to the curvilinear structure center, and the gradient antisymmetry with respect to the object boundary. Measuring the image gradient symmetry remarkably suppresses the disturbance introduced by rapid intensity changes along curvilinear structures. Meanwhile, considering the image gradient antisymmetry helps locate the structure boundary. The gradient symmetry and the gradient antisymmetry are evaluated based on the notion of oriented flux. By utilizing the aforementioned gradient symmetry information, an active contour model is tailored to perform segmentation. On the one hand, by exploiting the symmetric image gradient pattern observed at structure centers, the contours expand along curvilinear structures even through there exists intensity fluctuation along the structures. On the other hand, measuring the antisymmetry of the image gradient conveys strong detection responses to precisely drive contours to the structure boundaries, as well as avoiding contour leakages. The proposed method is capable of delivering promising segmentation results. This is validated in the experiments using synthetic data and real vascular images of different modalities, and through the comparison to two well founded and published methods for curvilinear structure segmentation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ناحیه‌بندی مرز اندوکارد بطن چپ در تصاویر تشدید مغناطیسی قلبی با شدت روشنایی غیریکنواخت

The stochastic active contour scheme (STACS) is a well-known and frequently-used approach for segmentation of the endocardium boundary in cardiac magnetic resonance (CMR) images. However, it suffers significant difficulties with image inhomogeneity due to using a region-based term based on the global Gaussian probability density functions of the innerouter regions of the active ...

متن کامل

A Deformable Vessel Model with Single Point Initialization for Segmentation, Quantification and Visualization of Blood Vessels in 3D MRA

We deal with image segmentation applied to three-dimensional (3D) analysis of vascular morphology in magnetic resonance angiography (MRA) images. The main goal of our work is to develop a fast and reliable method for stenosis quantification. The first step towards this purpose is the extraction of the vessel axis by an expansible skeleton method. Vessel boundaries are then detected in the plane...

متن کامل

Retinal Vessel Segmentation using Infinite Perimeter Active Contour with Hybrid Information Model

1P.G Scholar, E.G.S.Pillay Engineering College, Nagapattinam,Tamilnadu,India. 24Assistant Professor, E.G.S.Pillay Engineering College, Nagapattinam, Tamilnadu, India. 3Head Of the Department, E.G.S.Pillay Engineering College, Nagapattinam, Tamilnadu ,India. -------------------------------------------------------------------------------------------------------------------------------------------...

متن کامل

A New Computer-Aided Detection System for Pulmonary Nodule in CT Scan Images of Cancerous Patients

Introduction: In the lung cancers, a computer-aided detection system that is capable of detecting very small glands in high volume of CT images is very useful.This study provided a novelsystem for detection of pulmonary nodules in CT image. Methods: In a case-control study, CT scans of the chest of 20 patients referred to Yazd Social Security Hospital were examined. In the two-dimensional and ...

متن کامل

MRA Image Segmentation with Capillary Active Contour

Precise segmentation of three-dimensional (3D) magnetic resonance angiography (MRA) image can be a very useful computer aided diagnosis (CAD) tool in clinical routines. Our objective is to develop a specific segmentation scheme for accurately extracting vasculature from MRA images. Our proposed algorithm, called the capillary active contour (CAC), models capillary action where liquid can climb ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010