Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.

نویسندگان

  • S. M. Kim
  • W. J. Shim
  • H. E. Lim
  • G. S. Hwang
  • W. H. Song
  • D. S. Lim
  • Y. H. Kim
  • H. S. Seo
  • D. J. Oh
  • Y. M. Ro
چکیده

To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intracoronary injection of 18 microg adenosine. TTDE was performed at baseline and after intravenous adenosine (140 microg/kgmin for 2 min). Adequate Doppler recordings of coronary flow velocities during systole were obtained in 14 of 21 study patients (67%) and during diastole in 17 (81%) patients. Baseline and hyperemic peak diastolic flow velocities measured by TTDE were significantly smaller than those obtained by ICDW (p<0.05). However, diminishing trends of diastolic and systolic velocity ratio after hyperemia were similarly observed in both methods. CFR obtained by TTDE (3.0+/-0.5), was higher than the value calculated by ICDW (2.5+/-0.4). There were significant correlations between the values obtained by the two methods (r=0.72, p<0.01). It is concluded that TTDE is a feasible method in measuring coronary flow velocity and appears to be a promising non-invasive method in evaluating CFR.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Distal left circumflex coronary artery flow reserve recorded by transthoracic Doppler echocardiography: a comparison with Doppler-wire

BACKGROUND Coronary flow reserve (CFR) recording by means of transthoracic echocardiography (TTDE) in all the main distal coronary arteries is a challenge for advanced echocardiography. Validation studies of TTDE versus Doppler-wire (DW) recordings are available for Left Anterior Descending artery (LAD) and the Posterior Descending coronary artery (PD), but lacking for the more technically chal...

متن کامل

New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler.

BACKGROUND We tested the hypothesis that blood flow velocity could be recorded in the left anterior descending coronary artery (LAD) during transthoracic echocardiography by use of second harmonic echo Doppler modality along with contrast enhancement (intravenous Levovist) at rest and after pharmacologically induced maximal vasodilation to assess coronary flow reserve (CFR) with a totally nonin...

متن کامل

Assessment of flow velocity reserve by transthoracic Doppler echocardiography and venous adenosine infusion before and after left anterior descending coronary artery stenting.

OBJECTIVES We sought to evaluate whether coronary flow velocity reserve (CFR) (the ratio between hyperemic and baseline peak flow velocity), as measured by transthoracic Doppler echocardiography during adenosine infusion, allows detection of flow changes in the left anterior descending coronary artery (LAD) before and after stenting. BACKGROUND The immediate post-stenting evaluation of CFR by...

متن کامل

Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR) in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery). Post-sten...

متن کامل

Non-invasive measurement of coronary flow reserve in children with Kawasaki disease.

OBJECTIVE To investigate whether transthoracic Doppler echocardiography (TTE) can reliably measure the coronary flow reserve in the left anterior descending coronary artery in children with Kawasaki disease. DESIGN Coronary flow velocity in the distal left anterior descending coronary artery was measured by TTE and was compared with that obtained by intracoronary Doppler guide wire. The ratio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of Korean Medical Science

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2000