Placing a coronary stent during angioplasty minimizes reduces of acute vessel occlusion [1] and restenosis [2]. Although permanent metallic stents are effective in preventing recoil and late restenosis after coronary angioplasty, they continue to have limitations such as stent thrombosis and mismatch of the stent to the vessel size. In-stent restenosis is the major shortcoming of conventional (permanent-implant) stent therapy. To mitigate the adverse effects of metallic stents, drug-eluting stents have been developed. These also act as time-released delivery mechanisms for antiproliferative agents, thus further reducing restenosis. There is no clear advantage, however, of having stents remaining in the coronaries after they are endothelized. On the contrary, there are documented disadvantages since incomplete healing can induce a chronic inflammatory state increasing the risk for thrombosis [3]. Permanently implanted stents can also impair endothelial function [4], prevent late favourable remodelling [5], and hamper future imaging and reintervention. Thus, the concept of bioabsorbable stents has emerged as a viable alternative to permanent stents. The idea behind the bioabsorbable stents is to develop a device that provides scaffolding in the periprocedural phase and during short-term follow-up. Bioabsorbable stents, once they are bioabsorbed, leave behind only the healed natural vessel, allowing restoration of vasoreactivity with the potential of vessel remodelling. Late stent thrombosis is unlikely since the stent is gone, and prolonged antiplatelet therapy is not necessary in this instance. Bioabsorbable stents can also be suitable for complex anatomy where stents impede on vessel geometry and morphology and are prone to crushing and fractures, such as is seen in saphenous femoral and tibial arteries. Bioabsorbable implant stents can be used as a delivery device for agents such as drugs and genes, and will perhaps play a role in the treatment of vulnerable plaque [6]. In addition, drug-eluting bioabsorbable stents can deliver antiproliferative agents to reduce restenosis and then dissolve over time, thereby eliminating the disadvantages associated with permanent stents. In this paper we will briefly review the technology, preclinical, and initial clinical experimental studies regarding bioabsorbable stents.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thrombogenicity and early vascular healing response in metallic biodegradable polymer-based and fully bioabsorbable drug-eluting stents.

BACKGROUND Acute thrombogenicity and re-endothelialization represent clinically relevant end points pertaining to the safety of coronary stents, which have not been compared among biodegradable polymer-based drug-eluting metallic stents and fully bioabsorbable scaffolds to date. METHODS AND RESULTS We investigated comparative outcomes with respect to acute thrombogenicity and re-endothelializ...

متن کامل

Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent

Transcatheter treatment of children with congenital heart disease such as coarctation of the aorta and pulmonary artery stenosis currently involves the use of metal stents. While these provide good short term results, there are long term complications with their use. Children outgrow metal stents, obligating them to future transcatheter dilations and eventual surgical removal. A bioabsorbable s...

متن کامل

Preclinical Study of a Biodegradable Polymer-based Stent with Abluminal Sirolimus Release

BACKGROUND Bioabsorbable polymer stents with drug elution only on the abluminal surface may be safer than durable polymer drug-eluting stents. OBJECTIVE To report the experimental findings with the Inspiron™ stent - a bioabsorbable polymer-coated stent with sirolimus release from the abluminal surface only, recently approved for clinical use. METHODS 45 stents were implanted in the coronary...

متن کامل

Contemporary Reviews in Interventional Cardiology Bioabsorbable Coronary Stents

Percutaneous coronary intervention (PCI) with bioabsorbable stents has created interest because the need for mechanical support for the healing artery is temporary, and beyond the first few months there are potential disadvantages of a permanent metallic prosthesis. Stents improve immediate outcomes, including profoundly reducing acute vessel occlusion after PCI by scaffolding intimal tissue fl...

متن کامل

Next generation drug-eluting stents: focus on bioabsorbable platforms and polymers

The success of drug-eluting stents in preventing restenosis has shifted the focus of new stent development toward enhancing long term safety and efficacy of these devices, while simultaneously eliminating the need for indefinite dual antiplatelet therapy. A technical advance fulfilling these aims would hold tremendous potential to reduce morbidity, mortality and economic costs associated with t...