Accelerated susceptibility-based positive contrast imaging of MR compatible metallic devices based on modified fast spin echo sequences.

نویسندگان

  • Caiyun Shi
  • Guoxi Xie
  • Yongqin Zhang
  • Xiaoyong Zhang
  • Min Chen
  • Shi Su
  • Ying Dong
  • Xin Liu
  • Jim Ji
چکیده

This study aims to develop an accelerated susceptibility-based positive contrast MR imaging method for visualizing MR compatible metallic devices. A modified fast spin echo sequence is used to accelerate data acquisition. Each readout gradient in the modified fast spin echo is slightly shifted by a short distance T shift. Phase changes accumulated within T shift are then used to calculate the susceptibility map by using a kernel deconvolution algorithm with a regularized ℓ1 minimization. To evaluate the proposed fast spin echo method, three phantom experiments were conducted and compared to a spin echo based technique and the gold standard CT for visualizing biopsy needles and brachytherapy seeds. Compared to the spin echo based technique, the data sampling speed of the proposed method was faster by 2-4 times while still being able to accurately visualize and identify the location of the biopsy needle and brachytherapy seeds. These results were confirmed by CT images of the same devices. Results also demonstrated that the proposed fast spin echo method can achieve good visualization of the brachytherapy seeds in positive contrast and in different orientations. It is also capable of correctly differentiating brachytherapy seeds from other similar structures on conventional magnitude images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Potential positive MRI contrast agent based on PVP-grafted superparamagnetic iron oxide nanoparticles with various repetition times

Objective(s): The present study aimed to evaluate the capability of synthesized and modified superparamagnetic iron oxide nanoparticles (SPIONs) as the positive contrast agent in magnetic resonance imaging (MRI) by investigating the effect of repetition time (TR) on the MRI signal intensity. Materials and Methods: SPIONs were synthesized using the co-precipitation method, and their surfac...

متن کامل

Neuro MR: principles.

The principles of contrast mechanisms and fast pulse sequences underlying neurological and neuroradiological application of MRI are introduced in this part of a two-part review. In particular, the relaxation time constants T(1), T(2), and T(2) (*) are introduced, along with pulse sequences harnessing their contrast, spin-echo, fast spin echo (FSE), inversion recovery (IR), gradient recalled ech...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Development of a fluorescent screen based QA system for dose verification of afterloading HDR unit

Material and Methods: A total of six patients were included in this study. Each patient was scanned with one of two T2weighted sequences, inversion recovery fast spin echo (IR FSE) or fast recovery fast spin echo (FRFSE). To reduce the motion artefacts in the images, the scanning was only triggered when the diaphragm was at the end-exhale position. The imaging was performed on a 3.0 T MR (GE He...

متن کامل

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 62 7  شماره 

صفحات  -

تاریخ انتشار 2017