Three-dimensional reconstructed MRI of an acrylic meniscal cartilage phantom: The effect of acquisition slice thickness upon accuracy of volume measurement
نویسندگان
چکیده
3. Dr. Karen J. Reynolds School of Informatics and Engineering, Flinders University, GPO Box 2100, Adelaide, South Australia 5001 Tel: +61 8 8201 5190 Fax: +61 8 8201 3618 e-mail: [email protected] ABSTRACT The aim of this study was to determine the influence of slice thickness upon the accuracy of volume measurement taken from three-dimensional reconstructed magnetic resonance (MR) images. A pair of scaled meniscal cartilage phantoms (medial and lateral) were created from a low viscosity acrylic casting resin. The two phantoms were imaged simultaneously using a modified proton density turbo spin-echo (PD TSE) MR sequence at slice thicknesses of 4.0, 3.0, 2.0, 1.5 and 1.0mm. At each slice thickness, a three-dimensional reconstructed image of each phantom was created, using a commercially available software package. Using the software’s inbuilt analysis functions, a volume measurement was then made of each image. The software generated volume measures were compared to a “gold standard” mass/density measure of the phantoms. Percentage measurement error (PME) measures were calculated, with mean values ranging from 19.42% (4.0 mm slice thickness) to 1.05% (1.0 mm). Paired t testing suggested no statistically significant difference (P = 0.15) between the means of the PME values for the two phantoms suggesting an acceptable degree of measurement consistency. In conclusion, the results of this study suggest that the three-dimensional reconstructed technique can be used to achieve a highly accurate volume measurement (PME < 5%) of irregular (non-geometric) objects or image components (such as human meniscal cartilages) without the need to employ sub-millimetre acquisitions. Such slice thicknesses are within the capabilities of most commercial MR scanners, making the results reported here relevant to the majority of clinical imaging sites.
منابع مشابه
Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...
متن کامل[Computed tomography colonography image assessment using colon phantom-effects of reconstructed slice thickness].
Computed tomography colonography (CTC) is a robust and reliable imaging test of the colon. Recent studies show good sensitivity for the identification of nonpolypoid (flat) lesions as well. The purpose of this study was to determine the accuracy and reproducibility of a volume-rendering (VR) and virtual gross pathology (VGP) technique for detecting a polypoid lesion phantom by varying slice thi...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملDesign, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems
Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...