The accuracy of socket orientation using a pelvic fixation device for total hip arthroplasty with the patient in the lateral decubitus position in comparison to the vacuum bag fixation method.
نویسندگان
چکیده
BACKGROUND In our department, a vacuum bag with two lateral boards used to be utilized in order to maintain patients in the lateral decubitus position during THA. However, we recently changed this modality to a three-point fixation device for the pelvis in order to accurately control the position of the acetabular socket. The purpose of this study was to retrospectively compare the orientation of the acetabular socket when THA was carried out using two different positioning methods. METHODS Group 1 consisted of 66 hips that underwent THA in 1997 using a vacuum bag, which became rigid with suction. Group 2 consisted of 42 hips that were treated in 2000 using a three-point fixation device for the pelvis. This device was designed to able to rigidly fix the bilateral anterior superior iliac spines and the sacrum. Before fixation with the device, the angle between the line aligning the anterior-superior iliac spines and the vertical plane in the lateral decubitus position was measured as the lateral pelvic tilt. The orientation of the fixed acetabular socket was evaluated based on postoperative radiographs. RESULTS The average absolute value from 45 degrees in the abduction angle was significantly lower in group 2 than that in group 1 (p < 0.01). In 18% of the cases in group 1, the anteversion angle was over 30 degrees. In contrast, no such cases were observed in group 2. Postoperative dislocation occurred in six cases (9%) in group 1. In contrast, it only occurred in one case (2%) in group 2. CONCLUSIONS The positioning method using the pelvic fixation device enabled surgeons to more accurately control the position of the sockets during THA comparison to using the vacuum bag. The positioning of the patient is therefore suggested to be an important first step in successfully performing THA procedures.
منابع مشابه
Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem
The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...
متن کاملComparison of Clinical, Functional, and Radiological Outcomes of Total Knee Arthroplasty Using Conventional and Patient-Specific Instrumentation
Background: Recently, patient-specific instrumentation (PSI) systems have been developed in order to increase theaccuracy of component positioning during total knee arthroplasty (TKA); however, the findings of previous studies arecontroversial in this regard. In the current randomized clinical study, the outcomes of computer tomography (CT)-basedPS (patient specific)-guided TK...
متن کاملClinical Results of Percutaneous Fixation of Pelvic and Acetabular Fractures: A Minimally Invasive Internal Fixation Technique
Background: The pelvic ring fractures (PRF) and acetabular fractures (AF) are among the major orthopedic injuriesassociated with high rates of morbidity and mortality. Open surgical stabilization is the standard treatment for themajority of these complications. Percutaneous minimally invasive surgical stabilization of the fractures has become anaccepted treatment method for th...
متن کاملMagnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach
Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...
متن کاملTotal Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Fukuoka igaku zasshi = Hukuoka acta medica
دوره 98 1 شماره
صفحات -
تاریخ انتشار 2007