On the Zeros, Initial Undershoot, and Relative Degree of Collinear Lumped-Parameter Structures

نویسندگان

  • Jesse B. Hoagg
  • Jaganath Chandrasekar
  • Dennis S. Bernstein
چکیده

This paper considers collinear lumped-parameter structures where each mass in the structure has a single degree of freedom. Specifically, we analyze the zeros and relative degree of the single-input, single-output (SISO) transfer function from the force applied to an arbitrary mass to the position, velocity, or acceleration of another mass. In particular, we show that every SISO force-to-motion transfer function of a collinear lumpedparameter structure has no positive (real open-right-half-plane) zeros. In addition, every SISO force-to-position transfer function of a spring-connected collinear lumpedparameter structure has no non-negative (real closed-right-half-plane) zeros. As a consequence, the step response does not exhibit initial undershoot. In addition, we derive an expression for the relative degree of SISO force-to-position transfer functions. The formula depends on the placement of springs and dashpots, but is independent of the values of the spring constants and damping coefficients. Next, we consider the special case of serially connected collinear lumped-parameter structures. In this case, we show that every SISO force-to-position transfer function of a serially connected collinear lumpedparameter structure is minimum phase, that is, has no closed-right-half-plane zeros. The proofs of these results rely heavily on graph-theoretic techniques. DOI: 10.1115/1.2719764

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

LINEAR ESTIMATE OF THE NUMBER OF ZEROS OF ABELIAN INTEGRALS FOR A KIND OF QUINTIC HAMILTONIANS

We consider the number of zeros of the integral $I(h) = oint_{Gamma_h} omega$ of real polynomial form $omega$ of degree not greater than $n$ over a family of vanishing cycles on curves $Gamma_h:$ $y^2+3x^2-x^6=h$, where the integral is considered as a function of the parameter $h$. We prove that the number of zeros of $I(h)$, for $0 < h < 2$, is bounded above by $2[frac{n-1}{2}]+1$.

متن کامل

Dynamic Response of Submerged Vertical Cylinder with Lumped Mass under Seismic Excitation

An analytical approach is presented to assess the response of offshore structures under seismic excitation. This paper evaluates the impacts of different fluid field models and the mass of equipment at the top of offshore structure which is simulated as lumped mass on the responses of offshore structures. To do this, two and three dimensional fluid field models are developed. In three dimension...

متن کامل

On the $s^{th}$ derivative of a polynomial

For every $1leq s< n$, the $s^{th}$ derivative of a polynomial $P(z)$ of degree $n$ is a polynomial $P^{(s)}(z)$ whose degree is $(n-s)$. This paper presents a result which gives generalizations of some inequalities regarding the $s^{th}$ derivative of a polynomial having zeros outside a circle. Besides, our result gives interesting refinements of some well-known results.

متن کامل

A New Minimum Order Lumped-Parameter Model of Circulatory System for Patients with Suffered Left and Right-Sided Heart Failure

In this study a new minimum lumped electrical model of total circulatory system through numerical solutions to approximate the response of the human circulatory system was presented. Among five existent ventricular elastances as activity function of heart pumps, a more accurate model was chosen as well as the operation of baroreflex system to accommodate variations in heart rate and systemic va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007