Simultaneous Determination of Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD5) in Wastewater by Near-Infrared Spectrometry
نویسندگان
چکیده
To rapidly determine the pollution extent of wastewater, the calibration models were established for determination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater by partial least squares and near infrared spectrometry of 120 samples. Spectral data preprocessing and outliers’ diagnosis were also discussed. Correlation coefficients of the models were 0.9542 and 0.9652, and the root mean square error of prediction (RMSEP) were 25.24 mg·L and 12.13 mg·L in the predicted range of 28.40~528.0 mg·L and 16.0~305.2 mg·L for Chemical Oxygen Demand and Biological Oxygen Demand, respectively. By statistical significance test, the results of determination were compared with those of standard methods with no significant difference at 0.05 level. The method has been applied to simultaneous determination of Chemical Oxygen Demand and Biological Oxygen Demand in wastewater with satisfactory results.
منابع مشابه
Monitoring Urban Wastewaters’ Characteristics by Visible and Short Wave Near-Infrared Spectroscopy
On-line monitoring of wastewater parameters is a major scientific and technical challenge because of the great variability of wastewater characteristics and the extreme physical-chemical conditions that endure the sensors. Wastewater treatment plant managers require fast and reliable information about the input sewage and the operation of the different treatment stages. There is a great need fo...
متن کاملCalculation of sludge production from aerobic ASP based on COD and BOD5 – comparison of methods and model validation
A 5-day Biological Oxygen Demand (BOD5) is one of the parameters which are used to determine the amount of biodegradable organic substances in water environments. In dimensioning wastewater treatment plants, BOD5 is used for determining organic loading rates which enter the wastewater treatment plant and affect such parameters as surplus sludge production and oxygen demand. Conventional “static...
متن کاملModeling and optimization of oil refinery wastewater chemical oxygen demand removal in dissolved air flotation system by response surface methodology
In this present study the dissolved air flotation (DAF) system was investigated for the treatment of Kermanshah Oil Refinery wastewater. The effect of three parameters on flotation efficiency including of flow rate (outflow from the flotation tank), saturation pressure and coagulant dosage on chemical oxygen demand (COD) removal was examined experimentally. All the experiments were done under a...
متن کاملSimultaneous carbon and nitrogen removal from municipal wastewater in full-scale unaerated/aerated submerged filters.
Characterization and evaluation of a biological submerged filter was carried out on a full-scale pilot plant performing removal of biochemical oxygen demand (BOD) and total nitrogen (TN) from pre-treated urban wastewater. The average influent values of BOD5, chemical oxygen demand (COD) and TN were 370, 1,015 and 60 mg/L, respectively. The pilot plant produced good discharge quality during stea...
متن کاملEffect of Dissolved Oxygen and Chemical Oxygen Demand to Nitrogen Ratios on the Partial Nitrification/Denitrification Process in Moving bed Biofilm Reactors
Partial nitrification was reported to be technically feasible and economically favorable, especially for wastewaterwith high ammonium concentration or low C/N ratio. In this study, the effect of dissolved oxygen (DO)and influent ratio of chemical oxygen demand to nitrogen (COD/N) ratio on biological nitrogen removal fromsynthetic wastewater was investigated. Experiments were c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009