Readout of GEM Detectors Using the Medipix2 CMOS Pixel Chip

نویسندگان

  • A. Bamberger
  • P. Wienemann
چکیده

We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron multiplier (Triple-GEM) to detect the ionization from Fe X-rays and electrons from Ru. The device allows to perform moderate energy spectroscopy measurements (20 % FWHM at 5.9 keV X-rays) using only digital readout and two discriminator thresholds. Being a truly 2D-detector, it allows to observe individual clusters of minimum ionizing charged particles in Ar/CO2 (70:30) and He/CO2 (70:30) mixtures and to achieve excellent spatial resolution for position reconstruction of primary clusters down to ∼ 50 μm, based on the binary centroid determination method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit

A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 μm above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames conta...

متن کامل

New Method for Analysis of image sensor to produce and evaluate the image

In this paper, a new method for evaluating CMOS image sensors based on computer modeling and analysis is introduced. Image sensors are composed of different parts, each of which has a specific effect on image quality. Circuits of image sensors can be evaluated and analyzed using circuit simulators or theoretically, but these methods cannot help to produce the final image. In order to produce th...

متن کامل

New Developments and Future Perspectives of Gaseous Detectors

Gaseous detectors are fundamental components of all present and planned high energy physics experiments. Over the past decade two representatives (GEM, Micromegas) of the Micro-Pattern Gas Detector (MPGD) concept have become increasingly important; the high radiation resistance and excellent spatial and time resolution make them an invaluable tool to confront future detector challenges at the n...

متن کامل

1 M ar 2 00 4 Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode

In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 μm and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 μm pitch, directly used as the charge collecting a...

متن کامل

Single Event Effects in the Pixel readout chip for BTeV

In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 μm CMOS processes following radiation tolerant ...

متن کامل