Omnifit acetabular component: a solution to preventing and treating dislocation.

نویسندگان

  • S A Jones
  • A John
  • M Mahesen
  • A W Blom
  • R Wharton
  • G C Bannister
چکیده

PURPOSE To assess short- to medium-term outcome of the Omnifit constrained acetabular component in preventing dislocation in at-risk patients after total hip arthroplasty (THA). METHODS 81 patients (mean age, 77 years) underwent either primary or revision THA with an Omnifit constrained acetabular component and were followed up clinically and radiologically for a mean period of 24 months. RESULTS There was one dislocation and one revision for avulsion of the acetabulum. The remaining prostheses remained well fixed. CONCLUSIONS In the short- to medium-term, the Omnifit constrained acetabular component is effective in preventing primary and recurrent dislocation in at-risk patients. Long-term follow-up is needed to assess whether good fixation is maintained. The Omnifit acetabular cup is recommended for elderly patients with limited life expectancy and functional demands.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.

A high incidence of acetabular osteolysis (43%), associated with osteolytic lesions in the proximal femur (22.6%) and leading to a high revision rate, was experienced with the Omnifit total hip prosthesis. We reviewed the clinical and radiological results with 429 Omnifit total hips in 356 patients after a mean follow-up of 60 months. Time to revision and wear of the polyethylene liner with dif...

متن کامل

Posterior Hip Fracture -Dislocation Associated with Ipsilateral Intertrochantric Fracture; a Rare Case Report

Hip dislocation occurs when the femur does not break and the force is transmitted towards the hip joint leading to a posterior dislocation of the femoral head with or without posterior acetabular fracture. We present the case of a 26 year old patient involved in motor vehicle accident. Clinical and imaging (radiography, CT) examination revealed an intertrochanteric fracture associated with ipsi...

متن کامل

The angle-bore acetabular component and dislocation after revision of a failed total hip replacement.

We reviewed 1039 revision total hip replacements where an angle-bore acetabular component was used. After a mean follow-up of nine years (0 to 20.6), the incidence of revision for dislocation was 2.1% (22 revisions), a success rate of 97.9%. In 974 revisions, where the indication was other than dislocation, the success rate was 98.5%. Of the 65 revisions for dislocation, 58 (89.2%) were success...

متن کامل

The role of the transverse acetabular ligament in total hip arthroplasty.

We performed a systematic literature review to evaluate the role of the transverse acetabular ligament as a reference aid when determining acetabular component anteversion in total hip arthroplasty. We conducted a literature search in the MEDLINE, EMBASE and Pubmed databases using the key words 'transverse acetabular ligament' and 'arthroplasty'. Four studies published between 2006 and 2011, re...

متن کامل

Recurrent dislocation following hip replacement: brief report.

A new method of preventing recurrent dislocation following total hip replacement was described by Olerud and Karlstr#{246}m (1985). It involves augmentation of the acetabular component with a sector cut from another acetabular prosthesis and screwed to the original implant. This procedure was performed on three of our patients with recurrent dislocation, but in each case the hip continued to di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 15 2  شماره 

صفحات  -

تاریخ انتشار 2007