Estimating retrospective exposure of household humidifier disinfectants.

نویسندگان

  • D U Park
  • M C Friesen
  • H S Roh
  • Y Y Choi
  • J J Ahn
  • H K Lim
  • S K Kim
  • D H Koh
  • H J Jung
  • J H Lee
  • H K Cheong
  • S Y Lim
  • J H Leem
  • Y H Kim
  • D M Paek
چکیده

UNLABELLED We conducted a comprehensive humidifier disinfectant exposure characterization for 374 subjects with lung disease who presumed their disease was related to humidifier disinfectant use (patient group) and for 303 of their family members (family group) for an ongoing epidemiological study. We visited the homes of the registered patients to investigate disinfectant use characteristics. Probability of exposure to disinfectants was determined from the questionnaire and supporting evidence from photographs demonstrating the use of humidifier disinfectant, disinfectant purchase receipts, any residual disinfectant, and the consistency of their statements. Exposure duration was estimated as cumulative disinfectant use hours from the questionnaire. Airborne disinfectant exposure intensity (μg/m(3)) was estimated based on the disinfectant volume (ml) and frequency added to the humidifier per day, disinfectant bulk level (μg/ml), the volume of the room (m(3)) with humidifier disinfectant, and the degree of ventilation. Overall, the distribution patterns of the intensity, duration, and cumulative exposure to humidifier disinfectants for the patient group were higher than those of the family group, especially for pregnant women and patients ≤6 years old. Further study is underway to evaluate the association between the disinfectant exposures estimated here with clinically diagnosed lung disease. PRACTICAL IMPLICATIONS Retrospective exposure to household humidifier disinfectant as estimated here can be used to evaluate associations with clinically diagnosed lung disease due to the use of humidifier disinfectant in Korea. The framework, with modifications to account for dispersion and use patterns, can also be potentially adapted to assessment of other household chemical exposures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Exposure to Household Humidifier Disinfectants and Risk of Lung Injury: A Family-Based Study

BACKGROUND In South Korea, a cluster of acute lung disease patients included lung injury disease suspected of being caused by the use of humidifier disinfectants. We examined the relationship between humidifier disinfectant exposure and clinically diagnosed humidifier disinfectant-associated lung injury (HDLI) in a family-based study. METHODS This case-control study included 169 clinically co...

متن کامل

Evaluation report on the causal association between humidifier disinfectants and lung injury

OBJECTIVES As of November 2011, the Korean government recalled and banned humidifier disinfectants (HDs) from the market, because four case-control studies and one retrospective epidemiological study proved the association between HDs and lung injury of unknown cause. The report reviewed the causal role of HDs in lung injury based on scientific evidences. METHODS A careful examination on the ...

متن کامل

Inhalation Lung Injury Associated with Humidifier Disinfectants in Adults

We recently established a novel disease entity presented as progressive respiratory failure associated with the inhalation of humidifier disinfectants. In April 2011, we encountered a series of peripartum patients with complaints of respiratory distress of unknown etiology, which was an uncommon phenomenon. Accordingly, we created a multidisciplinary team comprising intensivists, radiologists, ...

متن کامل

Humidifier disinfectants, unfinished stories.

Once released into the air, humidifier disinfectants became tiny nano-size particles, and resulted in chemical bronchoalveolitis. Families had lost their most beloved members, and even some of them became broken. Based on an estimate of two million potential victims who had experienced adverse effects from the use of humidifier disinfectants, we can say that what we have observed was only the t...

متن کامل

Humidifier Disinfectants Are a Cause of Lung Injury among Adults in South Korea: A Community-Based Case-Control Study.

BACKGROUNDS An outbreak of lung injury among South Korean adults was examined in a hospital-based case-control study, and the suspected cause was exposure to humidifier disinfectant (HD). However, a case-control study with community-dwelling controls was needed to validate the previous study's findings, and to confirm the exposure-response relationship between HD and lung injury. METHODS Each...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2015