A New Algorithm for Image Reconstruction for Positron Emission Tomography
نویسندگان
چکیده
In Positron Emission Tomography, penalized iterative algorithms like MAP often results in over smooth reconstructions due to over penalizing nature of the assumed interacting potential. These algorithms fail to determine the density class of the estimate and hence penalize the pixels irrespective of the density class. In this work, a fuzzy logic based approach is proposed to model the prior which captures the nature of pixel-pixel interaction. Quantitative analysis shows that the proposed fuzzy rule based reconstruction algorithm is capable of producing comparable estimates when compared to MAP and MRP algorithms. The reconstructed images are sharper in nature and the presence of spatially confined minute features are well reconstructed due to the local nature of the penalizing fuzzy potential.
منابع مشابه
Detection of Alzheimer\\\\\\\'s Disease using Multitracer Positron Emission Tomography Imaging
Alzheimer's disease is characterized by impaired glucose metabolism and demonstration of amyloid plaques. Individual positron emission tomography tracers may reveal specific signs of pathology that is not readily apparent on inspection of another one. Combination of multitracer positron emission tomography imaging yields promising results. In this paper, 57 Alzheimer's disease neuroimaging ini...
متن کاملCalculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit
Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...
متن کاملRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملApproximate Variance Images for Penalized-Likelihood Image Reconstruction
We present a fairly simple procedure for computing new approximations for the pixel variances in images reconstructed by penalized-likelihoodmethods. The method enables the display of variance images, which can provide an indication of uncertainty that may be helpful in medical diagnosis and in evaluation of image reconstruction algorithms. Simulations of positron emission tomography (PET) scan...
متن کاملCharacteristics of Smoothing Filters to Achieve the Guideline Recommended Positron Emission Tomography Image without Harmonization
Objective(s): The aim of this study is to examine the effect of different smoothing filters on the image quality and SUVmax to achieve the guideline recommended positron emission tomography (PET) image without harmonization. Methods: We used a Biograph mCT PET scanner. A National Electrical Manufacturers Association (NEMA) the International Electrotechnical Commission (IEC) body phantom was fil...
متن کاملImproving Reconstructed Image Quality in a Limited-Angle Positron Emission Tomography System
Limited-angle positron emission tomography systems can be placed next to the anatomical area of interest, improving their spatial resolution and diagnostic sensitivity. However, the incomplete angular sampling makes the reconstruction process susceptible to image artifacts and anisotropic spatial resolution. In this work, I show that combining total variation (TV) minimization with the maximum ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2004