Fast 3D ultrashort echo-time spiral projection imaging using golden-angle: A flexible protocol for in vivo mouse imaging at high magnetic field.

نویسندگان

  • Charles R Castets
  • William Lefrançois
  • Didier Wecker
  • Emeline J Ribot
  • Aurélien J Trotier
  • Eric Thiaudière
  • Jean-Michel Franconi
  • Sylvain Miraux
چکیده

PURPOSE To develop a fast three-dimensional (3D) k-space encoding method based on spiral projection imaging (SPI) with an interleaved golden-angle approach and to validate this novel sequence on small animal models. METHODS A disk-like trajectory, in which each disk contained spirals, was developed. The 3D encoding was performed by tilting the disks with a golden angle. The sharpness was first calculated at different T2* values. Then, the sharpness was measured on phantom using variable undersampling ratios. Finally, the sampling method was validated by whole brain time-of-flight angiography and ultrasmall superparamagnetic iron oxide (USPIO) enhanced free-breathing liver angiography on mouse. RESULTS The in vitro results demonstrated the robustness of the method for short T2* and high undersampling ratios. In vivo experiments showed the ability to properly detect small vessels in the brain with an acquisition time shorter than 1 min. Free-breathing mice liver angiography showed the insensitivity of this protocol toward motions and flow artifacts, and enabled the visualization of liver motion during breathing. CONCLUSIONS The method implemented here allowed fast 3D k-space sampling with a high undersampling ratio. Combining the advantages of center-out spirals with the flexibility of the golden angle approach could have major implications for real-time imaging. Magn Reson Med 77:1831-1840, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast 3D EPR Imaging Using Spiral Magnetic Field Gradient

We report a fast 3D continuous wave (CW) electron paramagnetic resonance imaging (EPRI) technique using spiral magnetic field gradient. By spiraling the magnetic field gradient and stepping the main magnetic field, this approach acquired a 3D image in one sweep of the main magnetic field, enabling significant reduction of the imaging time. We demonstrated using a home-built L-band EPR system th...

متن کامل

Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA).

Sequences with ultrashort echo times enable new applications of MRI, including bone, tendon, ligament, and dental imaging. In this article, a sequence is presented that achieves the shortest possible encoding time for each k-space point, limited by pulse length, hardware switching times, and gradient performance of the scanner. In pointwise encoding time reduction with radial acquisition (PETRA...

متن کامل

Magnetic Resonance in Medicine 000:000–000 (2011) Ultrashort Echo Time Imaging Using Pointwise Encoding Time Reduction With Radial Acquisition (PETRA)

Sequences with ultrashort echo times enable new applications of MRI, including bone, tendon, ligament, and dental imaging. In this article, a sequence is presented that achieves the shortest possible encoding time for each k-space point, limited by pulse length, hardware switching times, and gradient performance of the scanner. In pointwise encoding time reduction with radial acquisition (PETRA...

متن کامل

Time-varying view angle tilting with spiral readout gradients.

The conventional Fourier-transform-based spin-echo sequence with a view angle tilting gradient during data acquisition can correct the in-plane distortion induced by a chemical shift or B0 field inhomogeneity. However, when extended for 3D applications, alternate k-space sampling can be beneficial for reducing the lengthy scan time. As spiral trajectories have high k-space acquisition efficienc...

متن کامل

Optimized 3D ultrashort echo time pulmonary MRI.

PURPOSE To optimize 3D radial ultrashort echo time MRI for high resolution whole-lung imaging. METHODS 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field-of-view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phanto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 77 5  شماره 

صفحات  -

تاریخ انتشار 2017