Evaluation of Accuracy of the Body Composition Measurements by the Bia Method
نویسندگان
چکیده
Purpose. the main purpose of this study is to verify the accuracy of body composition measurements by the bIA method, using tANItA 418 MA unit. Basic procedures. For purposes of our study we decided to use the type-A uncertainty evaluation method (statistical processing of mea sured data). to formulate diagnostic error for the bIA method we used typical (standard) error of measurement from differences between pairs of repeated measurements – which is in principle a mean error of the test. the research was carried out on a group of 10 students whose field of study is physical education and sport. These students were chosen from the total number of 74 students in such a way that they repre sent as wide range of fat fraction as possible. Representation of their fat fraction oscillated between 9.0 to 31.2% of body fat. Input value of body fat, which was the basic criterion for selection of students to the measurement etalon, was determined by the DEXA method. Main findings. We described the uncertainty (type A) in selected file of etalons by an ave rage value and by a standard deviation in percentage of fat: 0.13 ± 0.05. A diagnostic error of the method expressed by means of typical (standard) error of measurement was 0.38% of body fat. Conclusion. Considering the detected values of uncertainty (type A) and of typical error of measurement, we can conclude that measurement of body composition by the bIA method using tANItA 418 MA unit is sufficiently accurate for requirements of practical use. The necessary condition for the above mentioned measurement accuracy is a strict observance of standard measurement conditions.
منابع مشابه
Comparison of the predicting body fat equations during a maturation period in adolescent girls (12-16ys)
Validation of predicting fatness methods in the Iranian girls with respect to the maturity process could help to identify anthropometric risk factors. This study evaluate the accuracy of four body composition prediction equations in the teenager students in Hamadan city .Method: The anthropometry profile of 266 adolescent girls (12-16 ys) including ,weight (55.69±10.18 kg),body mass index (2...
متن کاملBioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women
Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...
متن کاملComparing the Accuracy of Waist-Hip Ratio Calculation by the BIA device versus the Manual Method
Nowadays, the Waist-Hip Ratio is considered one of the most important indices in predicting the risk of cardiovascular diseases. The usual method for calculating this index is by measuring the waist and hip circumferences with a measuring tape. However, bioelectrical impedance analysis (BIA) devices are also capable of calculating this ratio. Hence, the goal of this study was to calculate this ...
متن کاملComparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis
Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...
متن کاملEvaluation of leg-to-leg BIA in assessing body composition in high-school-aged males and females.
The current investigation was conducted to evaluate the accuracy of the Tanita 300WA leg-to-leg (LL) bioelectrical impedance analyzer (BIA) for measuring body composition in an American high-school-aged population. Body composition was determined in 77 students, comparing BIA measurements with the criterion, hydrostatic weighing (HW). Among the males, there were no significant differences found...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011