Multivariable Logistic Regression Model: A Novel Mathematical Model that Predicts Visual Field Sensitivity from Macular Ganglion Cell Complex Thickness in Glaucoma
نویسندگان
چکیده
PURPOSE To design a mathematical model that can predict the relationship between the ganglion cell complex (GCC) thickness and visual field sensitivity (VFS) in glaucoma patients. DESIGN Retrospective cross-sectional case series. METHOD Within 3 months from VFS measurements by the Humphrey field analyzer 10-2 program, 83 eyes underwent macular GCC thickness measurements by spectral-domain optical coherence tomography (SD-OCT). Data were used to construct a multiple logistic model that depicted the relationship between the explanatory variables (GCC thickness, age, sex, and spherical equivalent of refractive errors) determined by a regression analysis and the mean VFS corresponding to the SD-OCT scanned area. Analyses were performed in half or 8 segmented local areas as well as in whole scanned areas. A simple logistic model that included GCC thickness as the single explanatory variable was also constructed. The ability of the logistic models to depict the real GCC thickness/VFS in SAP distribution was analyzed by the χ2 test of goodness-of-fit. The significance of the model effect was analyzed by analysis of variance (ANOVA). RESULTS Scatter plots between the GCC thickness and the mean VFS showed sigmoid curves. The χ2 test of goodness-of-fit revealed that the multiple logistic models showed a good fit for the real GCC thickness/VFS distribution in all areas except the nasal-inferior-outer area. ANOVA revealed that all of the multiple logistic models significantly predicted the VFS based on the explanatory variables. Although simple logistic models also exhibited significant VFS predictability based on the GCC thickness, the model effect was less than that observed for the multiple logistic models. CONCLUSIONS The currently proposed logistic models are useful methods for depicting relationships between the explanatory variables, including the GCC thickness, and the mean VFS in glaucoma patients.
منابع مشابه
Measurement of macular structure-function relationships using spectral domain-optical coherence tomography (SD-OCT) and pattern electroretinograms (PERG)
BACKGROUND Retinal ganglion cell (RGC) death is a common cause of loss of vision during glaucoma. Pattern electroretinogram (PERG) is an objective measure of the central retinal function that correlates with macular GCL thickness. The aim of this study is to determine possible relationships between the N95 amplitude of pattern electroretinogram (PERGamp) and macular ganglion cell/inner plexifor...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملRelationship between visual field sensitivity and macular ganglion cell complex thickness as measured by spectral-domain optical coherence tomography.
PURPOSE To evaluate the strength and pattern of the relationship between visual field (VF) mean sensitivity (MS), assessed by standard automated perimetry (SAP), and macular ganglion cell complex thickness (GCCT), measured with spectral-domain optical coherence tomography (SD-OCT). METHODS Ninety-seven glaucoma patients were enrolled. GCCT, determined by ganglion cell complex (GCC) scanning, ...
متن کاملDifferences in Relationship Between Macular Inner Retinal Layer Thickness and Retinal Sensitivity in Eyes With Early and Progressed Glaucoma.
PURPOSE To determine if the relationship between retinal sensitivity and macular inner retinal layer thickness differs between primary open-angle glaucoma (POAG) with mild and advanced central visual field (VF) damage. METHODS One eye of 153 POAG patients was included. Using spectral-domain optical coherence tomography, we measured the average thickness of the macular ganglion cell-inner plex...
متن کاملConsistency of Structure-Function Correlation Between Spatially Scaled Visual Field Stimuli and In Vivo OCT Ganglion Cell Counts.
Purpose To investigate the effect of stimulus size and disease status on the structure-function relationship within the central retina, we correlated the differential light sensitivity (DLS) with Goldmann stimulus size I to V (GI-V) and optical coherence tomography (OCT) derived in vivo ganglion cell count per stimulus area (GCc) within the macular area in normal subjects and patients with earl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2014