Very, very late stent thrombosis triggered by in-stent neoatherosclerosis: optical coherence tomography findings

نویسندگان

  • Geovana A. João
  • Carlos Eduardo S. Portela
  • Luiz F. Ybarra
  • Philippe Généreux
  • Adriano Caixeta
چکیده

Corresponding author: Adriano Caixeta MD, PhD, Department of Cardiovascular Interventions, Hospital Israelita Albert Einstein, Av. Albert Einstein, 627 Morumbi, 05652-000 São Paulo, Brazil, phone: +55 11 2151 0434, fax: +55 11 3747 1035, e-mail: [email protected] Received: 5.01.2016, accepted: 6.01.2016. Very, very late stent thrombosis triggered by in-stent neoatherosclerosis: optical coherence tomography findings

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Drug-Coated Balloon Treatment of Very Late Stent Thrombosis Due to Complicated Neoatherosclerosis

We describe the treatment of a patient presenting with very-late stent thrombosis with the use of a drug-coated balloon. In this patient, optical coherence tomography disclosed that ruptured and complicated neoatherosclerosis was the underlying substrate responsible for the episode of very-late stent thrombosis. The potential use of drug-coated balloons in this unique scenario is discussed.

متن کامل

Failure Mechanisms and Neoatherosclerosis Patterns in Very Late Drug-Eluting and Bare-Metal Stent Thrombosis.

BACKGROUND There are few clinical studies on the pathophysiological mechanisms of very late stent thrombosis (VLST). We report optical coherence tomography findings in patients with VLST and compare the findings between bare-metal stents (BMS) and drug-eluting stents (DES). METHODS AND RESULTS We conducted a registry of stent thrombosis at 4 North American centers with optical coherence tomog...

متن کامل

Characteristics of Earlier Versus Delayed Presentation of Very Late Drug‐Eluting Stent Thrombosis: An Optical Coherence Tomographic Study

BACKGROUND The pathophysiology underlying very late drug-eluting stent (DES) thrombosis is not sufficiently understood. Using optical coherence tomography, we investigated characteristics of very late stent thrombosis (VLST) according to different onset times. METHODS AND RESULTS A total of 98 patients from 10 South Korean hospitals who underwent optical coherence tomography for evaluation of...

متن کامل

Neoatherosclerosis in Very Late Stenosis of Bare Metal Stent by Optical Coherence Tomography

Bare metal stents (BMS) continue to be widely used in patients with coronary artery disease undergoing percutaneous revascularization. Progressive luminal renarrowing has been reported late after BMS implantation resulting in a significant rate of stent failure events. We present a case of very late BMS failure due to in-stent restenosis where optical coherence tomography (OCT) was used to demo...

متن کامل

Clinical Implication of Optical Coherence Tomography-Based Neoatherosclerosis

Recent research has indicated neoatherosclerosis (NA), the de novo development of atherosclerosis within the neointimal region of the stented segment after coronary stent implantation, as a mechanism of late/very late stent thrombosis (VLST) and restenosis. This research is based on histologic and intravascular imaging studies. Optical coherence tomography (OCT) is an imaging tool that is super...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016