PURPOSE This retrospective study investigated the survival rate of 174 clasp-retained removable partial dentures (CR-RPDs) made at the Department of Prosthodontics of the Regensburg University Medical Center over a 25-year period (1984 to 2009). MATERIALS AND METHODS The study analyzed the frequency of and time to the fracture of clasps, connectors, or denture bases; the occurrence of caries or periodontal lesions; the loss of abutment teeth; and the necessity of maintenance procedures such as relining or treatment of pressure areas. RESULTS The median follow-up time of 3 years was calculated using the inverse Kaplan-Meier method. The 5-year survival rate (time to renewal) of all CR-RPDs was 96.4%; the 10-year survival rate was 89.8%. Fractures most frequently occurred in clasps (n = 28, 16.1%) followed by major connectors (n = 9, 5.1%) and minor connectors (n = 6, 3.4%). The 5-year event-free rate for clasp fracture was 80.4%; the 10-year event-free rate was 76.9%. Caries lesions on abutment teeth were seen in 31.6% of patients, and 35.6% showed inflammation of the periodontal tissue surrounding the abutment teeth. The 5-year event-free rate for caries was 58.4%; the 10-year rate was 39.6%. A frequent complication was loss of abutment teeth (n = 15), but this complication was not age-dependent. After insertion of their prostheses, one-third of patients (n = 53, 30.5%) showed pressure areas of the mucosa. Significantly more (P < .001) pressure areas were caused by prostheses of the mandible (39.6%) than by those of the maxilla (12.5%). CONCLUSIONS CR-RPDs showed a survival rate of approximately 90% after 10 years of oral service. The predominant complications during oral service were caries lesions, loss of abutment teeth, and fracture of clasps.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Evaluation of Removable Partial Dentures on the Periodontal Health of Abutment Teeth: A Retrospective Study

The aim of this retrospective study was to evaluate the effect of removable partial dentures in periodontal abutment teeth in relation to the type of denture support and design of RPD in a five-year worn period. Methods : A total of 64 patients with removable partial dentures (RPDs), participated in this study. It were examined ninety-one RPDs. There were seventy-five RPDs with clasp-retained a...

متن کامل

Flexibility of the Retentive Arm of Acetal Resin Clasp versus Cast Clasps- an in Vitro Study

Restoration of esthetics is an important factor to consider in the fabrication of a removable partial denture (RPD) . 1 Several types of polymers and metal alloys have been used in RPD construction. Frequently, RPD clasps made from the same alloy as the metal framework. The most common alloys used for clasps are cobalt-chromium (Co-Cr) alloy and gold and titanium alloys, although these may be u...

متن کامل

Patient’s Satisfaction with Removable Partial Dentures: A Retrospective Case Series

This retrospective clinical study aimed to assess patient's satisfaction with removable partial dentures (RPDs), as retention, chewing ability, aesthetics during the observation period. MATERIAL AND METHODS A total of 63 patients with RPDs, participated in this study. The following data was collected: Kennedy classification, denture design, denture support, satisfaction and success of RPD. ...

متن کامل

Finite Element Analysis of Stress Distribution in the Cast Clasps, Direct Retainers of a Removable Partial Denture

Objectives: The purpose of this study was to evaluate the stress distribution in the critical components of the removable partial denture the cast clasps. Materials andmethod:The three-dimensional models of the clasps were generated using three-dimensional measurements and investigated during loading, using the finite element stress analysis. Results:Although the loading influences the stressdi...

متن کامل

Direct retainers for distal-extension removable partial dentures.

Clinical observations at the University of Washington indicated that the wrought wire clasp assembly, the I-bar clasp assembly, and the L-bar clasp assembly yield similar results. A periodic recall system for patients with removable partial dentures has been in effect since 1976. Several thousand observations have been made by the faculty, and no special trend of problems has been noted that wo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of prosthodontics

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 2012