MR imaging of acute intracranial hemorrhage: findings on sequential spin-echo and gradient-echo images in a dog model.
نویسندگان
چکیده
Seven intraparenchymal hematomas (four venous and three arterial) were placed in the brains of six dogs in order to study the MR appearance of acute hemorrhage and to evaluate the effects of several variables on the signal intensity of the hematoma. MR imaging at 0.6 and 1.5 T was performed by using standard short and long TR spin-echo and low-flip-angle gradient-echo sequences. Sequential examinations were performed during the first week following hematoma creation. MR findings were compared with CT and postmortem examinations. Three patterns of signal intensity were observed, which varied according to the size (small vs large) and location (parenchymal vs intraventricular) of the hematomas. The small parenchymal hematomas did not undergo evolutionary changes. On short TR scans they were isointense at both field strengths, and therefore not detectable; on long TR scans these hematomas were of variable intensity at 1.5 T and were hyperintense at 0.6 T. On gradient-echo scans, they were hypointense at all times at both field strengths. The large parenchymal hematomas underwent evolutionary changes typical of those seen in clinical imaging. On short TR scans they were initially isointense and became hyperintense 1-3 days later. Long TR scans demonstrated initial hyperintensity, followed by the development of hypointensity within 12 hr in the venous hematomas and within 60 hr in the arterial hematoma. The intensity changes on long TR scans were seen at both 0.6 and 1.5 T, but occurred sooner and to a greater degree at 1.5 T. Gradient-echo imaging of these large lesions demonstrated hypointensity at all times at both field strengths. The intraventricular hemorrhages demonstrated more rapid development of hyperintensity on short TR scans and slower and less pronounced development of hypointensity on long TR scans compared with the parenchymal clots in the same animal. Gradient-echo imaging of the intraventricular hemorrhages demonstrated hypointensity at all times at both field strengths. A multifactorial hypothesis is proposed to explain the differences in intensity between venous, arterial, and intraventricular blood. Gradient-echo sequences should prove to be highly useful in detecting and delineating hemorrhages and are recommended for the MR protocol of patients with acute neurologic ictus and suspected hemorrhage.
منابع مشابه
Detection of intracranial hemorrhage: comparison between gradient-echo images and b0 images obtained from diffusion-weighted echo-planar sequences on 3.0T MRI.
In this study, we compared the effectiveness of b0 echo-planar MR images (EPI) imaging with gradient recalled echo (GRE) in detecting acute hemorrhage. Brain images in 69 patients who suffered from acute infarction were reviewed. Nine of them had suffered from acute hemorrhage. Comparing b0EPI and GRE images side-by-side, we found no significant different effectiveness in detecting hemorrhage (...
متن کاملAssessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملاندازه گیری غیریکنواختی امواج رادیوئی در ام آر آی
Introduction: Non-uniformity is one of the most important parameters affecting MRI images which can lead to harmful effects in the diagnosis and analysis of qualitative and quantitative methods. The present study introduced a method for measuring RF non-homogeneity in MRI systems. Methods and Materials: To verify the uniformity of B0 and B1 fields, a cylindrical phantom with a diameter of 24 c...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملHyperacute subarachnoid hemorrhage on T2-weighted MR images.
We describe a case of hyperacute subarachnoid and intraventricular hemorrhage from a ruptured aneurysm, which occurred while the patient was undergoing MR imaging. Compared with CSF, the blood in the subarachnoid space had slightly lower signal intensity on T2*-weighted gradient-echo images and increased signal intensity on T2-weighted spin-echo images. This finding differs from the generally a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 12 3 شماره
صفحات -
تاریخ انتشار 1991