Large-scale generic test stand for testing of multiple configurations of air filters utilizing a range of particle size distributions.
نویسندگان
چکیده
The Institute for Clean Energy Technology (ICET) at Mississippi State University has developed a test stand capable of lifecycle testing of high efficiency particulate air filters and other filters specified in American Society of Mechanical Engineers Code on Nuclear Air and Gas Treatment (AG-1) filters. The test stand is currently equipped to test AG-1 Section FK radial flow filters, and expansion is currently underway to increase testing capabilities for other types of AG-1 filters. The test stand is capable of producing differential pressures of 12.45 kPa (50 in. w.c.) at volumetric air flow rates up to 113.3 m(3)/min (4000 CFM). Testing is performed at elevated and ambient conditions for temperature and relative humidity. Current testing utilizes three challenge aerosols: carbon black, alumina, and Arizona road dust (A1-Ultrafine). Each aerosol has a different mass median diameter to test loading over a wide range of particles sizes. The test stand is designed to monitor and maintain relative humidity and temperature to required specifications. Instrumentation is implemented on the upstream and downstream sections of the test stand as well as on the filter housing itself. Representative data are presented herein illustrating the test stand's capabilities. Digital images of the filter pack collected during and after testing is displayed after the representative data are discussed. In conclusion, the ICET test stand with AG-1 filter testing capabilities has been developed and hurdles such as test parameter stability and design flexibility overcome.
منابع مشابه
High-efficiency particulate air filter test stand and aerosol generator for particle loading studies.
This manuscript describes the design, characterization, and operational range of a test stand and high-output aerosol generator developed to evaluate the performance of 30 x 30 x 29 cm(3) nuclear grade high-efficiency particulate air (HEPA) filters under variable, highly controlled conditions. The test stand system is operable at volumetric flow rates ranging from 1.5 to 12 standard m(3)/min. R...
متن کاملارزیابی پارامترهای عملکردی در فیلترهای هپا در یک صنعت دارویی(مطالعه موردی1394)
Abstract: Background and aims: Nowadays, cleanrooms have become impartible parts of an industry with sensitive products. Sources of contamination in cleanrooms are impaired performance and quality sensitive products in the cleanrooms .The aim of this study was to evaluate the efficiency of HEPA filter and check the concentration and number of airborne particles in cleanrooms for pharmaceutic...
متن کاملComputer Simulation of Particle Size Classification in Air Separators
Cement powder size classification efficiency significantly affects quality of final product and extent of energy consumption in clinker grinding circuits. Static and dynamic or high efficiency air separators are being used widely in closed circuit with multi-compartment tube ball mills, High Pressure Grinding Rolls (HPGR) and more recently Vertical Roller Mills (VRM) units in cement plants ...
متن کاملA New Solution for the Cyclic Multiple-Part Type Three-Machine Robotic Cell Problem based on the Particle Swarm Meta-heuristic
In this paper, we develop a new mathematical model for a cyclic multiple-part type threemachine robotic cell problem. In this robotic cell a robot is used for material handling. The objective is finding a part sequence to minimize the cycle time (i.e.; maximize the throughput) with assumption of known robot movement. The developed model is based on Petri nets and provides a new method to calcul...
متن کاملپهنهبندی آلودگی فلزات سنگین در کلاسهای اندازه ذرات خاک براساس دادههای ماهواره Landsat ETM+ در جنوب شهر اصفهان
This research was carried out to determine spatial distribution of heavy metals concentration in soil particle size classes using Landsat ETM+ reflectance in Southern Isfahan city in the vicinity of Bama mine. To fulfill this goal, 100 compound soil surface samples were collected randomly from the area. The samples were air dried and soil particle size classes 250-500, 125-250, 75-125, 50-75 an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 83 5 شماره
صفحات -
تاریخ انتشار 2012