Evaluation of two vitallium blade-form implants retrieved after 13 to 21 years of function: a clinical report.

نویسندگان

  • Periklis Proussaefs
  • Jaime Lozada
چکیده

This article describes the clinical, radiographic, and histologic evaluation of 2 immediately loaded Vitallium blade-form implants retrieved from the posterior maxilla of 2 patients after 21 and 13 years of function. Neither implant demonstrated mobility or signs of pathosis, and both appeared to have integrated well with surrounding bone. The hydroxyapatite coating of the second implant, which was retrieved after 13 years of function, showed no dissolution. These observations suggest that immediately loaded dental implants have the potential to achieve and maintain osseointegration and that hydroxyapatite coatings can resist degradation over long-term service.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Element solubility from dental implants.

Six kinds of dental implants: Apaceram, Bioceram, Free design blade implant, Shape memory blade implant, Hydroxyapatite-coating blade implant and Vitallium were immersed in three kinds of solutions: Ringer's solution, 1.0% lactate acid solution, and 0.05% HCl solution, for seven days at 37•Ž. Using an inductively coupled plasma emission spectroscope, the solutions were analyzed. The element sol...

متن کامل

Histologic evaluation of hydroxyapatite-coated root-form implant retrieved after 7 years in function: a case report.

This case report presents a clinical, radiographic, and histologic evaluation of 2 non-adjacent, hydroxyapatite-coated, root-form implants retrieved from the maxillary canine area of a patient after 7 years in function. Clinical examination revealed immobile implants with no sign of pathosis. Radiographic examination indicated close proximity of the bone to the implant surface without evidence ...

متن کامل

Outcome of short implants as an alternative to sinus lift surgery and standard-length implants for rehabilitation of atrophic posterior maxilla: A clinical trial

Background and Aims: The aim of this study was to assess the outcome of short implants (<8 mm length) as an alternative to sinus lift surgery and placement of standard-length implants (10-12 mm length) for rehabilitation of atrophic posterior maxilla. Materials and Methods: In this prospective clinical trial, 26 patients with 6-7 mm of residual alveolar bone height in their atrophic posterior ...

متن کامل

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....

متن کامل

Clinical evaluation of soft tissue surrounding prosthesis supported by implants

Clinical evaluation of soft tissue surrounding prosthesis supported by implants Dr. A. Fazel* - Dr. M. Rismanchian** *- Associate Professor of Prosthodontics Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry - Isfahan University of Medical Sciences. Background and Aim: Nowadays, reconstruction and replace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of prosthetic dentistry

دوره 87 4  شماره 

صفحات  -

تاریخ انتشار 2002