Motion Aspects in Joint Image Reconstruction and Nonrigid Motion Estimation

نویسندگان

  • Young Chun
  • Charles R. Meyer
  • Selim Esedoglu
چکیده

MOTION ASPECTS IN JOINT IMAGE RECONSTRUCTION AND NONRIGID MOTION ESTIMATION by Se Young Chun Chair: Jeffrey A. Fessler Many medical imaging applications often require relatively long image acquisition times to form high-SNR images. However, long scan times can lead to motion artifacts. Conventional acquisition and reconstruction methods must sacrifice enough measurements for less motion artifacts or vice versa. Motion-compensated image reconstruction (MCIR) methods use all collected measurements, but reduce motion artifacts by incorporating motion information into the image reconstruction framework. Several motion incorporation schemes in MCIR have showed superior performance over image reconstruction methods without motion information. However, there has been little research that emphasizes the motion aspects of MCIR. This dissertation addresses a few issues of MCIR methods in motion aspects. First of all, we investigated methods for motion regularization. The usual choice for a motion regularizer in MCIR has been an elastic regularizer. Recently, there has been much research on regularizing nonrigid deformations with two different motion priors. Convenxiv tional methods that enforce deformations to be locally invertible require high computational complexity and large memory. We developed a sufficient condition that guarantees the local invertibility and proposed a simple regularizer based on that sufficient condition. Using both motion invertibility and rigid motion priors may cause conflicts near the diaphragm and the rib cage. We relaxed our motion invertibility regularizer to reduce undesirable bone warping yet better match the image intensities between deformed and target images and permits discontinuous deformations near the sliding area. Secondly, we studied the statistical properties of MCIR, showing that all MCIR methods are closely related to one another. This study also showed how motion affects the spatial resolution and noise properties of MCIR. We designed spatial regularizers to provide approximately uniform spatial resolution for MCIR. These regularizers enabled different MCIR methods to approximately have the same resolution. Noise properties were compared based on these regularizers. Lastly, we investigated joint image reconstruction and nonrigid motion estimation with different spatial and motion regularizers and regularization parameters. We performed a 4D PET simulation with lesions. Most MCIR methods produced better-quality images with better SNR and less motion blur. The proposed motion invertibility regularizer allowed more flexibility of deformation estimates compared to a conventional quadratic motion regularizer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Joint image reconstruction and nonrigid motion estimation with a simple penalty that encourages local invertibility

Motion artifacts are a significant issue in medical image reconstruction. There are many methods for incorporating motion information into image reconstruction. However, there are fewer studies that focus on deformation regularization in motioncompensated image reconstruction. The usual choice for deformation regularization has been penalty functions based on the assumption that tissues are ela...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

Marker-free motion correction in weight-bearing cone-beam CT of the knee joint.

PURPOSE To allow for a purely image-based motion estimation and compensation in weight-bearing cone-beam computed tomography of the knee joint. METHODS Weight-bearing imaging of the knee joint in a standing position poses additional requirements for the image reconstruction algorithm. In contrast to supine scans, patient motion needs to be estimated and compensated. The authors propose a meth...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

Structure and motion of nonrigid object under perspective projection

The paper focuses on the problem of structure and motion of nonrigid object from image sequence under perspective projection. Many previous methods on this problem utilize the extension technique of SVD factorization based on rank constraint to the tracking matrix, where the 3D shape of nonrigid object is expressed as a weighted combination of a set of shape bases. All these solutions are based...